Aptamer decorated PDA@magnetic silica microparticles for bacteria purification
buir.contributor.author | Babaie, Zahra | |
buir.contributor.author | Kibar, Güneş | |
buir.contributor.author | Çetin, Barbaros | |
buir.contributor.orcid | Kibar, Güneş|0000-0002-2586-6770 | |
buir.contributor.orcid | Çetin, Barbaros|0000-0001-9824-4000 | |
dc.citation.epage | 285-13 | |
dc.citation.issueNumber | 5 | |
dc.citation.spage | 285-1 | |
dc.citation.volumeNumber | 191 | |
dc.contributor.author | Kavruk, Murat | |
dc.contributor.author | Babaie, Zahra | |
dc.contributor.author | Kibar, Güneş | |
dc.contributor.author | Çetin, Barbaros | |
dc.contributor.author | Yeşilkaya, Hasan | |
dc.contributor.author | Amrani, Yassine | |
dc.contributor.author | Dursun, Ali Doğan | |
dc.contributor.author | Özalp, Veli Cengiz | |
dc.date.accessioned | 2025-02-20T18:27:11Z | |
dc.date.available | 2025-02-20T18:27:11Z | |
dc.date.issued | 2024-05 | |
dc.department | Institute of Materials Science and Nanotechnology (UNAM) | |
dc.department | Department of Mechanical Engineering | |
dc.description.abstract | One significant constraint in the advancement of biosensors is the signal-to-noise ratio, which is adversely affected by the presence of interfering factors such as blood in the sample matrix. In the present investigation, a specific aptamer binding was chosen for its affinity, while exhibiting no binding affinity towards non-target bacterial cells. This selective binding property was leveraged to facilitate the production of magnetic microparticles decorated with aptamers. A novel assay was developed to effectively isolate S. pneumoniae from PBS or directly from blood samples using an aptamer with an affinity constant of 72.8 nM. The capture experiments demonstrated efficiencies up to 87% and 66% are achievable for isolating spiked S. pneumoniae in 1 mL PBS and blood samples, respectively. | |
dc.identifier.doi | 10.1007/s00604-024-06322-3 | |
dc.identifier.issn | 0026-3672 | |
dc.identifier.uri | https://hdl.handle.net/11693/116526 | |
dc.language.iso | English | |
dc.publisher | SPRINGER Wien | |
dc.relation.isversionof | https://dx.doi.org/10.1007/s00604-024-06322-3 | |
dc.rights | CC BY 4.0 DEED (Attribution 4.0 International) | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.source.title | Microchimica Acta | |
dc.subject | Biosensor | |
dc.subject | Aptamer | |
dc.subject | Aptasensor | |
dc.subject | SELEX | |
dc.subject | Superparamagnetic | |
dc.subject | Microbeads | |
dc.title | Aptamer decorated PDA@magnetic silica microparticles for bacteria purification | |
dc.type | Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Aptamer_decorated_PDA@magnetic_silica_microparticles_for_bacteria.pdf
- Size:
- 5.7 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: