Theoretical and experimental limits of monodisperse droplet generation

Limited Access
This item is unavailable until:
2023-01-16

Date

2021-01-16

Editor(s)

Advisor

Supervisor

Co-Advisor

Co-Supervisor

Instructor

Source Title

Chemical Engineering Science

Print ISSN

0009-2509

Electronic ISSN

Publisher

Elsevier Ltd

Volume

229

Issue

Pages

116093-1 - 116093-7

Language

English

Journal Title

Journal ISSN

Volume Title

Series

Abstract

Droplet microfluidic systems are becoming routine in advanced biochemical studies such as single cell gene expression, immuno profiling, precise nucleic acid quantification (dPCR) and particle synthesis. For all these applications, ensuring droplet monodispersity is critical to minimize the uncertainty due to droplet volume variation. Despite the wide usage of droplet-based microfluidic systems, the limit of monodispersity for droplet generation systems is still unknown. Here, we present an analytical approach that takes into account all the system dynamics and internal/external factors that disturb monodispersity. Interestingly, we are able to model the dynamics of a segmented two-phase flow system using a single-phase flow analogy, electron flow, in electrical circuits. We offer a unique solution and design guidelines to ensure ultra-monodisperse droplet generation. Our analytical conclusions are experimentally verified using a T-junction droplet generator. Equally importantly, we show the limiting experimental factors for reaching the theoretical maximum of monodispersity.

Course

Other identifiers

Book Title

Citation