A phase aberration correction method for ultrasound imaging
buir.contributor.author | Atalar, Abdullah | |
buir.contributor.author | Köymen, Hayrettin | |
buir.contributor.orcid | Atalar, Abdullah|0000-0002-1903-1240 | |
dc.citation.epage | 282 | en_US |
dc.citation.issueNumber | 4 | en_US |
dc.citation.spage | 275 | en_US |
dc.citation.volumeNumber | 40 | en_US |
dc.contributor.author | Karaman, M. | en_US |
dc.contributor.author | Atalar, Abdullah | en_US |
dc.contributor.author | Köymen, Hayrettin | en_US |
dc.contributor.author | O'Donnell, M. | en_US |
dc.date.accessioned | 2016-02-08T10:54:08Z | |
dc.date.available | 2016-02-08T10:54:08Z | |
dc.date.issued | 1993 | en_US |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.description.abstract | A computationally efficient method for phase aberration correction in ultrasound imaging is presented. The method is based on time delay estimation via minimization of the sum of absolute differences between radio frequency samples of adjacent array elements. Effects of averaging estimated aberration patterns over scan angles, and truncation to a single bit wordlength are examined. Phase distortions due to near-field inhomogeneities are simulated using silicone rubber aberrators. Performance of the method is tested using experimental data. Simulation studies addressing different factors affecting efficiency of the method, such as the number of iterations, window length, and the number of scan angles used for averaging, are presented. Images of a standard resolution phantom are reconstructed and used for qualitative testing. | en_US |
dc.description.provenance | Made available in DSpace on 2016-02-08T10:54:08Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 1993 | en |
dc.identifier.doi | 10.1109/58.251275 | en_US |
dc.identifier.issn | 0885-3010 | |
dc.identifier.uri | http://hdl.handle.net/11693/26041 | |
dc.language.iso | English | en_US |
dc.publisher | IEEE | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1109/58.251275 | en_US |
dc.source.title | IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | en_US |
dc.subject | Image reconstruction | en_US |
dc.subject | Imaging techniques | en_US |
dc.subject | Mathematical models | en_US |
dc.subject | Phase aberration correction | en_US |
dc.subject | Radio frequency samples | en_US |
dc.subject | Standard resolution phantom | en_US |
dc.subject | Sum of absolute differences | en_US |
dc.subject | Ultrasonic imaging | en_US |
dc.title | A phase aberration correction method for ultrasound imaging | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Phase aberration correction method for ultrasound imaging.pdf
- Size:
- 803.79 KB
- Format:
- Adobe Portable Document Format
- Description:
- Full printable version