Detection and quantification of seasonal human heat and cold stress frequencies in representative existing and future urban canyons: the case of Ankara

buir.contributor.authorNouri, Andre Santos
buir.contributor.authorAfacan, Yasemin
buir.contributor.orcidNouri, Andre Santos|0000-0001-8084-3339
buir.contributor.orcidAfacan, Yasemin|0000-0002-0148-5033
dc.citation.epage620en_US
dc.citation.spage593
dc.citation.volumeNumber153
dc.contributor.authorNouri, Andre Santos
dc.contributor.authorCharalampopoulos, I.
dc.contributor.authorAfacan, Yasemin
dc.contributor.authorMatzarakis, A.
dc.date.accessioned2024-03-19T11:43:33Z
dc.date.available2024-03-19T11:43:33Z
dc.date.issued2023-05-27
dc.departmentDepartment of Interior Architecture and Environmental Design
dc.description.abstractBased upon a ‘human-centred approach’, combinations of existing and new methodologies were applied to determine how Ankara’s morphological characteristics influenced the magnitude/frequency of Cold Stress (CS) and Heat Stress (HS) to detect/quantify seasonal and yearly human thermal stress frequency. To quantify these conditions upon the human biometeorological system, the Physiologically Equivalent Temperature (PET) was utilised by processing climatic variables from Ankara’s Meteorological Station (AMS). In situ assessments of human thermophysiological thresholds were undertaken within characteristic existing/future Urban Canyon Cases (UCCs), with a further stipulation of three interior Reference Points (RPs). Indoor PET values were moreover calculated within a stereotypical vulnerable residential dwelling. Seasonal frequencies revealed that winter PET values frequently ranged between 0.0 and − 19.9 °C, with corresponding summer values frequently ranging between 35.1 and 46.0 °C. Accounting for Ankara’s urban morphology, yearly frequency of No Thermal Stress remained at ~ 48%, CS remained at ~ 26%, and HS ~ 28%. HS varied the most between the eight evaluated Aspect Ratios (ARs). It reduced by up to 7.1% (114 min) within the Centre (RP$_{C}$) area of UCCs with an orientation of 90°. Out of twelve orientations, the highest HS frequency took place between 105 and 135°. Including in UCC$_{3.50}$, the frequency of HS almost always remained above 72% (2592 min).
dc.description.provenanceMade available in DSpace on 2024-03-19T11:43:33Z (GMT). No. of bitstreams: 1 Detection_and_quantification_of_seasonal_human_heat_and_cold_stress_frequencies_in_representative_existing_and_future_urban_canyons_the_case_of_Ankara.pdf: 7909608 bytes, checksum: 402566675bc82bc1ac1764f0bfc368e4 (MD5) Previous issue date: 2023-05-27en
dc.identifier.doi10.1007/s00704-023-04482-5
dc.identifier.eissn1434-4483
dc.identifier.issn0177-798X
dc.identifier.urihttps://hdl.handle.net/11693/114979
dc.language.isoen
dc.publisherSpringer Wien
dc.relation.isversionofhttps://dx.doi.org/10.1007/s00704-023-04482-5
dc.rightsCC BY 4.0 DEED (Attribution 4.0 International)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.source.titleTheoretical and Applied Climatology
dc.titleDetection and quantification of seasonal human heat and cold stress frequencies in representative existing and future urban canyons: the case of Ankara
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Detection_and_quantification_of_seasonal_human_heat_and_cold_stress_frequencies_in_representative_existing_and_future_urban_canyons_the_case_of_Ankara.pdf
Size:
7.54 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.01 KB
Format:
Item-specific license agreed upon to submission
Description: