Experimental characterization of capacitive micromachined ultrasonic transducers
buir.contributor.author | Atalar, Abdullah | |
buir.contributor.author | Köymen, Hayrettin | |
buir.contributor.orcid | Atalar, Abdullah|0000-0002-1903-1240 | |
dc.citation.epage | 2134 | en_US |
dc.citation.spage | 2131 | en_US |
dc.contributor.author | Ölçüm, Selim | en_US |
dc.contributor.author | Atalar, Abdullah | en_US |
dc.contributor.author | Köymen, Hayrettin | en_US |
dc.contributor.author | Oğuz, Kağan | en_US |
dc.contributor.author | Şenlik, Muhammed N. | en_US |
dc.coverage.spatial | New York, NY, USA | en_US |
dc.date.accessioned | 2016-02-08T11:42:01Z | |
dc.date.available | 2016-02-08T11:42:01Z | |
dc.date.issued | 2007 | en_US |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.description | Date of Conference: 28-31 October 2007 | en_US |
dc.description | Conference Name: Ultrasonics Symposium, IEEE 2007 | en_US |
dc.description.abstract | In this paper, capacitive micromachined ultrasonic transducers are fabricated using a sacrificial surface micromachining process. A testing procedure has been established in order to measure the absolute transmit and receive sensitivity spectra of the fabricated devices. The experiments are performed in oil. Pulse-echo experiments are performed and the results are compared to the pitch-catch measurements using calibrated transducers. | en_US |
dc.description.provenance | Made available in DSpace on 2016-02-08T11:42:01Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2007 | en |
dc.identifier.doi | 10.1109/ULTSYM.2007.536 | en_US |
dc.identifier.issn | 1051-0117 | |
dc.identifier.uri | http://hdl.handle.net/11693/27017 | |
dc.language.iso | English | en_US |
dc.publisher | IEEE | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1109/ULTSYM.2007.536 | en_US |
dc.source.title | Proceedings of the Ultrasonics Symposium, IEEE 2007 | en_US |
dc.subject | Capacitive micromachined ultrasonic transducers | en_US |
dc.subject | cMUT | en_US |
dc.subject | Electroacoustic transducers | en_US |
dc.subject | Experiments | en_US |
dc.subject | Flow of fluids | en_US |
dc.subject | Micromachining | en_US |
dc.subject | Optical design | en_US |
dc.subject | Transducers | en_US |
dc.subject | Ultrasonic equipment | en_US |
dc.subject | Ultrasonic measurement | en_US |
dc.subject | Ultrasonic waves | en_US |
dc.subject | Ultrasonics | en_US |
dc.subject | Experimental characterization | en_US |
dc.subject | Fabricated devices | en_US |
dc.subject | Pitch-catch | en_US |
dc.subject | Pulse echoes | en_US |
dc.subject | Surface micromachining processes | en_US |
dc.subject | Testing procedures | en_US |
dc.subject | Ultrasonic transducers | en_US |
dc.title | Experimental characterization of capacitive micromachined ultrasonic transducers | en_US |
dc.type | Conference Paper | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Experimental characterization of capacitive micromachined ultrasonic transducers.pdf
- Size:
- 221.27 KB
- Format:
- Adobe Portable Document Format
- Description:
- Full printable version