Multiplexed cell-based diagnostic devices for detection of renal biomarkers
buir.contributor.author | Köse, Sıla | |
buir.contributor.author | Ahan, Recep Erdem | |
buir.contributor.author | Köksaldı, İlkay Çisil | |
buir.contributor.author | Şeker, Urartu Özgür Şafak | |
buir.contributor.orcid | Köse, Sıla|0000-0003-1243-5602 | |
buir.contributor.orcid | Ahan, Recep Erdem|0000-0002-6061-9062 | |
buir.contributor.orcid | Köksaldı, İlkay Çisil|0000-0002-3121-4939 | |
buir.contributor.orcid | Şeker, Urartu Özgür Şafak|0000-0002-5272-1876 | |
dc.citation.epage | 115035-8 | en_US |
dc.citation.spage | 115035-1 | |
dc.citation.volumeNumber | 223 | |
dc.contributor.author | Köse, Sıla | |
dc.contributor.author | Ahan, Recep Erdem | |
dc.contributor.author | Köksaldı, İlkay Çisil | |
dc.contributor.author | Olgaç, A. | |
dc.contributor.author | Kasapkara, Çiğdem S. | |
dc.contributor.author | Şeker, Urartu Özgür Şafak | |
dc.date.accessioned | 2024-03-12T12:44:11Z | |
dc.date.available | 2024-03-12T12:44:11Z | |
dc.date.issued | 2022-12-24 | |
dc.department | Institute of Materials Science and Nanotechnology (UNAM) | |
dc.description.abstract | The number of synthetic biology-based solutions employed in the medical industry is growing every year. The whole cell biosensors being one of them, have been proven valuable tools for developing low-cost, portable, personalized medicine alternatives to conventional techniques. Based on this concept, we targeted one of the major health problems in the world, Chronic Kidney Disease (CKD). To do so, we developed two novel biosensors for the detection of two important renal biomarkers: urea and uric acid. Using advanced gene expression control strategies, we improved the operational range and the response profiles of each biosensor to meet clinical specifications. We further engineered these systems to enable multiplexed detection as well as an AND-logic gate operating system. Finally, we tested the applicability of these systems and optimized their working dynamics inside complex medium human blood serum. This study could help the efforts to transition from labor-intensive and expensive laboratory techniques to widely available, portable, low-cost diagnostic options. | |
dc.embargo.release | 2024-12-24 | |
dc.identifier.doi | 10.1016/j.bios.2022.115035 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.uri | https://hdl.handle.net/11693/114607 | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | |
dc.relation.isversionof | https://doi.org/10.1016/j.bios.2022.115035 | |
dc.rights | CC BY 4.0 Deed (Attribution 4.0 International) | |
dc.rights.uri | https://creativecommons.org/licenses/by/2.0/ | |
dc.source.title | Biosensors and Bioelectronics | |
dc.subject | Synthetic biology | |
dc.subject | Whole cell sensor | |
dc.subject | Urea | |
dc.subject | Uric acid | |
dc.title | Multiplexed cell-based diagnostic devices for detection of renal biomarkers | |
dc.type | Article |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Multiplexed_cell-based_diagnostic_devices_for_detection_of_renal_biomarkers.lnk
- Size:
- 2.04 KB
- Format:
- Unknown data format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.01 KB
- Format:
- Item-specific license agreed upon to submission
- Description: