BUIR logo
Communities & Collections
All of BUIR
  • English
  • Türkçe
Log In
Please note that log in via username/password is only available to Repository staff.
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Olçum, Selim"

Filter results by typing the first few letters
Now showing 1 - 3 of 3
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Deep collapse mode capacitive micromachined ultrasonic transducers
    (2010) Olçum, Selim
    Capacitive micromachined ultrasonic transducers (CMUTs) are suspended microelectromechanical membrane structures with a moving top electrode and a rigid substrate electrode. The membrane is actuated by electrical signals applied between the electrodes, resulting in radiated pressure waves. CMUTs have several advantages over traditional piezoelectric transducers such as their wider bandwidth and microfabrication methodology. CMUTs as microelectromechanical systems (MEMS), are fabricated using CMOS compatible processes and suitable for batch fabrication. Low cost production of large amount of CMUTs can be fabricated using already established integrated circuit (IC) technology infrastructure. Contrary to piezoelectrics, fabricating large 2-D arrays populated with transducer elements using CMUTs is low-cost. The technological challenges of CMUTs regarding the fabrication and integration issues were solved during the past 15 years, and their successful operation has been demonstrated in many applications. However, commercialization of CMUTs is still an overdue passion for CMUT community. The bandwidth of the CMUTs are inherently superior to their piezoelectric rivals due to the nature of the suspended membrane structure, however, their power output capability must be improved to achieve superior signal-to-noise ratio and penetration depth. In this thesis, we gave a comprehensive discussion about the physics and functionality of CMUTs and showed both theoretically and experimentally that their power outputs can be increased substantially. Using the conventional uncollapsed mode of CMUTs, where the suspended membrane vibrates freely, the lumped displacement of the membrane is limited. Limited displacement, unfortunately, limits the power output of the CMUT. However, a larger lumped displacement is possible in the collapsed state, where the membrane gets in contact with the substrate. By controlling the movement of the membrane in this state, the power output of the CMUTs can be increased. We derived the analytical expressions for the profile of a circular CMUT membrane in both uncollapsed and collapsed states. Using the profiles, we calculated the forces acting on the membrane and the energy radiated to the medium during an applied electrical pulse. We showed that the radiated energy can be increased drastically by utilizing the nonlinear forces on the membrane, well beyond the collapse voltage. Using the analytical expressions, we developed a nonlinear electrical equivalent circuit model that can be used to simulate the mechanical behavior of a transmitting CMUT under any electrical excitation. Furthermore, the model can handle different membrane dimensions and material properties. It can predict the membrane movement in the collapsed state as well as in the uncollapsed state. In addition, it predicts the hysteretic snap-back behavior of CMUTs, when the electric potential across a collapsed membrane is decreased. The nonlinear equivalent circuit was simulated using SPICE circuit simulator, and the accuracy of the model was tested using finite element method (FEM) simulations. Better than 3% accuracy is achieved for the static deflection of a membrane as a function of applied DC voltage. On the other hand, the pressure output of a CMUT under large signal excitation is predicted within 5% accuracy. Using the developed model, we explained the dynamics of a CMUT membrane. Based on our physical understanding, we proposed a new mode of operation, the deep collapse mode, in order to generate high power acoustic pulses with large bandwidth (>100% fractional) at a desired center frequency. We showed both by simulation (FEM and equivalent circuit) and by experiments that the deep collapse mode increases the output pressure of a CMUT, substantially. The experiments were performed on CMUTs fabricated at Bilkent University by a sacrificial release process. Larger than 3.5 MPa peak-to-peak acoustic pulses were measured on CMUT surface with more than 100% fractional bandwidth around 7 MHz using an electrical pulse amplitude of 160 Volts. Furthermore, we optimized the deep collapse mode in terms of CMUT dimensions and parameters of the applied electrical pulse, i.e., amplitude, rise and fall times, pulse width and polarity. The experimental results were compared to dynamic FEM and equivalent circuit simulations. We concluded that the experimental results are in good agreement with the simulations. We believe that CMUTs, with their high transmit power capability in the deep collapse mode can become a strong competitor to piezoelectrics.
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Interaction between a cMUT cell and a liquid medium around the parallel resonance frequency
    (IEEE, 2007-10) Şenlik, Muhammed N.; Atalar, Abdullah; Olçum, Selim
    In this paper, we present how a capacitive micromachined ultrasonic transducer (cMUT) couples to the immersion medium, based on an accurate parametric model. We show that the velocity of cMUT membrane can be written as a sum of an average velocity term and a residual term. We demonstrate that this residual term carries non-zero energy at the parallel resonance frequency by investigating the interaction between the cMUT cell and a liquid medium. We develop a model that is also applicable around the parallel resonance frequency. © 2007 IEEE.
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers
    (2005) Olçum, Selim
    Capacitive micromachined ultrasonic transducers (cMUT) have large bandwidths, but they typically have low conversion efficiencies. This thesis defines a performance measure in the form of a gain-bandwidth product, and investigates the conditions in which this performance measure is maximized. A Mason model corrected with finite element simulations is utilized for the purpose of optimizing parameters. There are different performance measures for transducers operating in transmit, receive or pulse-echo modes. Basic parameters of the transducer are optimized for those operating modes. Optimized values for a cMUT with silicon nitride membrane and immersed in water are given. The effect of including an electrical matching network is considered. In particular, the effect of a shunt inductor in the gain-bandwidth product is investigated. Design tools are introduced, which are used to determine optimal dimensions of cMUTs with the specified frequency or gain response.

About the University

  • Academics
  • Research
  • Library
  • Students
  • Stars
  • Moodle
  • WebMail

Using the Library

  • Collections overview
  • Borrow, renew, return
  • Connect from off campus
  • Interlibrary loan
  • Hours
  • Plan
  • Intranet (Staff Only)

Research Tools

  • EndNote
  • Grammarly
  • iThenticate
  • Mango Languages
  • Mendeley
  • Turnitin
  • Show more ..

Contact

  • Bilkent University
  • Main Campus Library
  • Phone: +90(312) 290-1298
  • Email: dspace@bilkent.edu.tr

Bilkent University Library © 2015-2025 BUIR

  • Privacy policy
  • Send Feedback