Saturation Coil for Localized Signal Suppression in MPI
buir.contributor.author | Kor, Ege | |
buir.contributor.author | Arslan, Musa Tunç | |
buir.contributor.author | Saritas, Emine Ulku | |
buir.contributor.orcid | Kor, Ege |0000-0002-3128-0645 | |
buir.contributor.orcid | Arslan, Musa Tunç |0000-0001-6698-838X | |
buir.contributor.orcid | Saritas, Emine Ulku | 0000-0001-8551-1077 | |
dc.citation.epage | 3 | en_US |
dc.citation.issueNumber | 1Suppl 1 | en_US |
dc.citation.spage | 1 | en_US |
dc.citation.volumeNumber | 8 | en_US |
dc.contributor.author | Kor, Ege | |
dc.contributor.author | Arslan, Musa Tunç | |
dc.contributor.author | Saritas, Emine Ulku | |
dc.date.accessioned | 2023-02-25T14:27:22Z | |
dc.date.available | 2023-02-25T14:27:22Z | |
dc.date.issued | 2022 | |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.description.abstract | The magnetic nanoparticles (MNPs) used as imaging tracers in magnetic particle imaging (MPI) accumulate in off-target organs such as liver or spleen. The signal from the high-concentration MNPs in these off-target organs may overpower the signals from the nearby low-concentration regions targeted during imaging. In this work, we propose using a saturation coil to suppress the localized high intensity MPI signal from the off-target accumulation organs. The results of the proof-of-concept imaging experiments show that, when the saturation coil is placed over the high-concentration region, it can selectively and completely suppress the signal from that region. | en_US |
dc.description.provenance | Submitted by Mandana Moftakhari (mandana.mir@bilkent.edu.tr) on 2023-02-25T14:27:22Z No. of bitstreams: 1 Saturation_coil_for_localized_signal_suppression_in_MP.pdf: 1371484 bytes, checksum: 9c9c38276543f8a2bc4c2c917659fd63 (MD5) | en |
dc.description.provenance | Made available in DSpace on 2023-02-25T14:27:22Z (GMT). No. of bitstreams: 1 Saturation_coil_for_localized_signal_suppression_in_MP.pdf: 1371484 bytes, checksum: 9c9c38276543f8a2bc4c2c917659fd63 (MD5) Previous issue date: 2022 | en |
dc.identifier.doi | 10.18416/IJMPI.2022.2203013 | en_US |
dc.identifier.eissn | 2365-9033 | |
dc.identifier.uri | http://hdl.handle.net/11693/111743 | |
dc.language.iso | English | en_US |
dc.publisher | Infinite Science Publishing | en_US |
dc.relation.isversionof | https://doi.org/10.18416/IJMPI.2022.2203013 | en_US |
dc.source.title | International Journal on Magnetic Particle Imaging | en_US |
dc.title | Saturation Coil for Localized Signal Suppression in MPI | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Saturation_coil_for_localized_signal_suppression_in_MP.pdf
- Size:
- 1.31 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.69 KB
- Format:
- Item-specific license agreed upon to submission
- Description: