Detectivity of YBCO transition edge bolometer: Modulation frequency, bias current and absorber effects

dc.citation.issueNumber1en_US
dc.citation.volumeNumber97en_US
dc.contributor.authorMoftakharzadeh, A.en_US
dc.contributor.authorKokabi, A.en_US
dc.contributor.authorBozbey, A.en_US
dc.contributor.authorGhods-Elahi, T.en_US
dc.contributor.authorVesaghi, M.en_US
dc.contributor.authorKhorasani, S.en_US
dc.contributor.authorBanzet, M.en_US
dc.contributor.authorSchubert J.en_US
dc.contributor.authorFardmanesh, M.en_US
dc.date.accessioned2016-02-08T10:10:25Z
dc.date.available2016-02-08T10:10:25Z
dc.date.issued2008en_US
dc.departmentDepartment of Electrical and Electronics Engineeringen_US
dc.description.abstractBolometric response and noise characteristics of YBCO superconductor transition edge IR detectors with relatively sharp transition and its resulting detectivity are investigated both theoretically and experimentally. The magnitude of response of a fabricated device was obtained for different bias currents and modulation frequencies. Also dependency of intrinsic noise of the device on the bias current in the vicinity of critical temperature was studied for various values of chopping frequencies. Using the measured and calculated bolometric response and noise characteristics, we found and analyzed the device detectivity versus frequency for different bias currents. The detectivity versus chopping frequency of the device did not decrease following the response strongly, due to the decrease of the noise at higher frequencies up to 1KHz, resulting in maximum detectivity around the modulation frequency of 100Hz. We also improved the detectivity of the device through the increase of the surface absorption by using a novel infrared absorber, which is made of a Copper-Carbon composite, coated in a low temperature process. Within the modulation frequency range studied in this investigation, comparison of device responsivity before and after the coating is also presented. © 2008 IOP Publishing Ltd.en_US
dc.description.provenanceMade available in DSpace on 2016-02-08T10:10:25Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2008en
dc.identifier.doi10.1088/1742-6596/97/1/012009en_US
dc.identifier.issn17426588
dc.identifier.urihttp://hdl.handle.net/11693/23217
dc.language.isoEnglishen_US
dc.relation.isversionofhttp://dx.doi.org/10.1088/1742-6596/97/1/012009en_US
dc.source.titleJournal of Physics: Conference Seriesen_US
dc.titleDetectivity of YBCO transition edge bolometer: Modulation frequency, bias current and absorber effectsen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Detectivity of YBCO transition edge bolometer Modulation frequency, bias current and absorber effects.pdf
Size:
876.38 KB
Format:
Adobe Portable Document Format
Description:
Full printable version