Fabrication and optimization of rf-SQUID and SQUID integration assembly for high resolution magnetic imaging systems

buir.advisorFardmanesh, Mehdi
dc.contributor.authorAkram, Rizwan
dc.date.accessioned2016-07-01T11:03:26Z
dc.date.available2016-07-01T11:03:26Z
dc.date.issued2005
dc.departmentDepartment of Electrical and Electronics Engineeringen_US
dc.descriptionCataloged from PDF version of article.en_US
dc.description.abstractSuperconducting QUantum Interference Devices or SQUIDs are by far the most sensitive devices known for sensing magnetic flux down to a resolution of about 10−21Wb and finds innumerous applications in various fields. In order to apply these sensors to sense nano structures or to use in antibody or antigen ammunoassay experiments, especially in unshielded environments at Liquid Nitrogen temperatures, one needs to optimize the SQUIDs for high SNR and low background magnetic field sensitivity. The chief motivation for this research work and this thesis is to optimize and characterize HTc rf-SQUIDs so that high field sensitivity and high spatial resolution could be obtained. During the course of this study, rf-SQUIDs were fabricated using SEJ and Bicrystal technology and optimized for the above mentioned characteristics. In the next stage, these optimized sensors were integrated into an imaging system after a thorough investigation on problems related to the front-end assembly of such a system. Different SQUID microscope systems have been designed, fabricated, and tested in order to achieve high field sensitivity and high spatial resolution magnetic imaging under the constraint of keeping the sample at room temperature, while the SQUID is in Liquid Nitrogen Temperature. Using the developed systems, magnetic imaging of room temperature samples with sensitivities in the range of about 100fT/√ (Hz) and spatial resolution of about 100 µm were achieveden_US
dc.description.degreePh.D.en_US
dc.description.provenanceMade available in DSpace on 2016-07-01T11:03:26Z (GMT). No. of bitstreams: 1 0002909.pdf: 9037899 bytes, checksum: b31a5df1294004d747c177338fce4022 (MD5) Previous issue date: 2005en
dc.description.statementofresponsibilityAkram, Rizwanen_US
dc.format.extentxxiii, 181 leaves, illustrationsen_US
dc.identifier.itemidBILKUTUPB093791
dc.identifier.urihttp://hdl.handle.net/11693/29700
dc.language.isoEnglishen_US
dc.publisherBilkent Universityen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSuperconductoren_US
dc.subjectYBCOen_US
dc.subjectJosephson Junctionen_US
dc.subjectStep Edge junctionen_US
dc.subjectBicrystal junctionen_US
dc.subjectrf-SQUIDen_US
dc.subjectScanning SQUID microscopeen_US
dc.subject.lccQC612.S8 A47 2005en_US
dc.subject.lcshSuperconductors.en_US
dc.titleFabrication and optimization of rf-SQUID and SQUID integration assembly for high resolution magnetic imaging systemsen_US
dc.typeThesisen_US