Susceptibility Artifacts

dc.citation.epage105en_US
dc.citation.spage91en_US
dc.contributor.authorSaritas, E. U.en_US
dc.contributor.authorHoldsworth, S. J.en_US
dc.contributor.authorBammer, R.en_US
dc.date.accessioned2018-04-12T13:37:40Z
dc.date.available2018-04-12T13:37:40Z
dc.date.issued2014en_US
dc.departmentDepartment of Electrical and Electronics Engineeringen_US
dc.description.abstractIn vivo magnetic resonance imaging of the spinal cord is challenging due to susceptibility variations between various tissue types, air in the lungs and trachea, and in some cases surgical implants that significantly distort the applied magnetic field. These field inhomogeneities create off-resonance induced artifacts in the images, such as signal dropouts and pileups, geometric distortions, and incomplete fat suppression. Bulk physiologic motion from cardiac and respiratory cycles, cerebrospinal fluid pulsation, as well as breathing and swallowing further cause temporal variations of these field inhomogeneities. Moreover, the anatomy of the spine requires a relatively large field of view (FOV), especially in the sagittal imaging plane, while the small cross-sectional size of the spinal cord mandates high-spatial-resolution images. The resulting long readout duration, especially that of echo planar imaging (EPI), further exacerbates the artifacts. This chapter reviews susceptibility artifacts, their impact on EPI of the spinal cord, and methods to limit these artifacts. Acquisition-based methods include multishot imaging, parallel acquisitions, reduced-FOV methods, and non-EPI techniques. Reconstruction-based methods involve distortion correction, phase correction, and other advanced techniques.en_US
dc.description.provenanceMade available in DSpace on 2018-04-12T13:37:40Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 179475 bytes, checksum: ea0bedeb05ac9ccfb983c327e155f0c2 (MD5) Previous issue date: 2014en
dc.identifier.doi10.1016/B978-0-12-396973-6.00007-1en_US
dc.identifier.isbn9780123969736
dc.identifier.urihttp://hdl.handle.net/11693/37778
dc.language.isoEnglishen_US
dc.publisherElsevier Inc.en_US
dc.relation.isversionofhttp://dx.doi.org/10.1016/B978-0-12-396973-6.00007-1en_US
dc.source.titleQuantitative MRI of the Spinal Corden_US
dc.subjectDistortionen_US
dc.subjectEcho-planar imaging (EPI)en_US
dc.subjectField inhomogeneityen_US
dc.subjectOff-resonanceen_US
dc.subjectSignal dropouten_US
dc.subjectSignal pileupen_US
dc.subjectSusceptibility artifactsen_US
dc.titleSusceptibility Artifactsen_US
dc.typeBook Chapteren_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Susceptibility Artifacts.pdf
Size:
2.55 MB
Format:
Adobe Portable Document Format
Description:
Full printable version