Frequency optimization in high intensity focused ultrasound
dc.citation.epage | 412 | en_US |
dc.citation.spage | 409 | en_US |
dc.contributor.author | Yetik, H. | en_US |
dc.contributor.author | Arıyurek, Cemre | en_US |
dc.contributor.author | Bozkurt, A. | en_US |
dc.contributor.author | Ergun, A. S. | en_US |
dc.coverage.spatial | Chicago, IL, USA | |
dc.date.accessioned | 2016-02-08T12:01:42Z | |
dc.date.available | 2016-02-08T12:01:42Z | |
dc.date.issued | 2014-09 | en_US |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.description | Date of Conference: 3-6 Sept. 2014 | |
dc.description | Conference name: 2014 IEEE International Ultrasonics Symposium | |
dc.description.abstract | In high intensity focused ultrasound (HIFU) the choice of transducer frequency depends on the target depth and tissue type. At high frequencies attenuation does not permit enough acoustical power to be transmitted to the target whereas at low frequencies the transmitted power is not absorbed efficiently. Hence, there exists an optimum frequency at which the power deposited at the target is maximum. In this study, we verified this relation experimentally using MR compatible focused transducers, ex-vivo tissue samples and magnetic resonance (MR) thermometry. © 2014 IEEE. | en_US |
dc.description.provenance | Made available in DSpace on 2016-02-08T12:01:42Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2014 | en |
dc.identifier.doi | 10.1109/ULTSYM.2014.0101 | en_US |
dc.identifier.uri | http://hdl.handle.net/11693/27785 | |
dc.language.iso | English | en_US |
dc.publisher | IEEE | en_US |
dc.relation.isversionof | https://doi.org/10.1109/ULTSYM.2014.0101 | en_US |
dc.source.title | IEEE International Ultrasonics Symposium, IUS 2014 | en_US |
dc.subject | Tissue | en_US |
dc.subject | Transducers | en_US |
dc.subject | Ultrasonics | en_US |
dc.subject | Acoustical power | en_US |
dc.subject | Focused transducer | en_US |
dc.subject | Frequency optimization | en_US |
dc.subject | High frequency HF | en_US |
dc.subject | High intensity focused ultrasound | en_US |
dc.subject | MR-compatible | en_US |
dc.subject | Optimum frequency | en_US |
dc.subject | Transmitted power | en_US |
dc.subject | Magnetic resonance | en_US |
dc.title | Frequency optimization in high intensity focused ultrasound | en_US |
dc.type | Conference Paper | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Frequency_optimization_in_high_intensity_focused_ultrasound.pdf
- Size:
- 119.23 KB
- Format:
- Adobe Portable Document Format
- Description: