Preventing interference between saturation coil and receive coil in MPI

buir.contributor.authorKor, Ege
buir.contributor.authorArslan, Musa Tunç
buir.contributor.authorTakrimi, Manouchehr
buir.contributor.authorSarıtaş, Emine Ülkü
buir.contributor.orcidKor, Ege|0000-0002-3128-0645
buir.contributor.orcidArslan, Musa Tunç|0000-0001-6698-838X
buir.contributor.orcidTakrimi, Manouchehr|0000-0001-5515-2472
buir.contributor.orcidSarıtaş, Emine Ülkü|0000-0001-8551-1077
dc.citation.epage4
dc.citation.issueNumber1
dc.citation.spage1
dc.citation.volumeNumber10
dc.contributor.authorKor, Ege
dc.contributor.authorArslan, Musa Tunç
dc.contributor.authorTakrimi, Manouchehr
dc.contributor.authorSarıtaş, Emine Ülkü
dc.date.accessioned2025-02-13T11:40:35Z
dc.date.available2025-02-13T11:40:35Z
dc.date.issued2024-03-20
dc.departmentDepartment of Electrical and Electronics Engineering
dc.departmentNational Magnetic Resonance Research Center (UMRAM)
dc.description.abstractIn magnetic particle imaging (MPI), the signals received from magnetic nanoparticles (MNPs) are directly proportional to concentration. Hence, accumulation of MNPs in off-target organs may overpower the signal from actual regions-of-interest that contain MNPs at a smaller concentration. We previously proposed placing a saturation coil over the off-target organ to locally suppress its signal. However, the saturation coil caused a large interference signal on the receive coil, necessitating the acquisition of a separate baseline to determine the interference signal. In this work, we propose methods to prevent the interference between the saturation coil and the receive coil to enable localized signal suppression without the need for an additional baseline acquisition. © 2024 Kor et al.; licensee Infinite Science Publishing GmbH.
dc.identifier.doi10.18416/IJMPI.2024.2403003
dc.identifier.eissn2365-9033
dc.identifier.urihttps://hdl.handle.net/11693/116242
dc.language.isoEnglish
dc.publisherInfinite Science Publishing
dc.relation.isversionofhttps://doi.org/10.18416/IJMPI.2024.2403003
dc.rightsCC BY 4.0 DEED (Attribution 4.0 International)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.source.titleInternational Journal on Magnetic Particle Imaging
dc.subjectNanoparticle
dc.subjectMagnetic field
dc.subjectParticle imaging
dc.titlePreventing interference between saturation coil and receive coil in MPI
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Preventing_interference_between_saturation_coil_and_receive_coil_in_MPI.pdf
Size:
979.26 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: