Design of internal MRI coils using ultimate intrinsic SNR

buir.contributor.authorAtalar, Ergin
dc.citation.epage228en_US
dc.citation.issueNumber4en_US
dc.citation.spage221en_US
dc.citation.volumeNumber22en_US
dc.contributor.authorEryaman, Y.en_US
dc.contributor.authorÖner, Y.en_US
dc.contributor.authorAtalar, Erginen_US
dc.date.accessioned2016-02-08T10:03:07Z
dc.date.available2016-02-08T10:03:07Z
dc.date.issued2009-09-27en_US
dc.departmentDepartment of Electrical and Electronics Engineeringen_US
dc.description.abstractObject: Internal MRI coils have important applications in diagnostic and interventional studies. Since they can be placed very close to the region of interest in the body, they are favored over external coils in applications where high-resolution images are required. In this paper it is demonstrated that ultimate intrinsic SNR (UISNR) and the optimum coil sensitivity solutions can be used to make new coil designs with higher intrinsic SNR. Materials and methods: In this study, UISNR, which is the maximum attainable value of the intrinsic SNR, is used as a measure of performance and as a design criterion. As an example, a novel endorectal MRI coil is designed. The design is tested with phantom and patient studies. Results: An endorectal coil is built to demonstrate the effectiveness of the design strategy. ISNR of the endorectal coil approximates the UISNR to 72%. Conclusion: An internal coil design method that takes advantage of the UISNR and optimum coil sensitivity calculations was presented. This method can also be used to design better internal MRI coils for different applications.en_US
dc.description.provenanceMade available in DSpace on 2016-02-08T10:03:07Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2009en
dc.identifier.doi10.1007/s10334-009-0167-1en_US
dc.identifier.issn0968-5243
dc.identifier.urihttp://hdl.handle.net/11693/22666
dc.language.isoEnglishen_US
dc.publisherSpringeren_US
dc.relation.isversionofhttp://dx.doi.org/10.1007/s10334-009-0167-1en_US
dc.source.titleMagnetic Resonance Materials in Physics, Biology and Medicineen_US
dc.subjectInternal MRI coilsen_US
dc.subjectIntrinsic SNRen_US
dc.subjectUltimate intrinsic SNRen_US
dc.titleDesign of internal MRI coils using ultimate intrinsic SNRen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Design of internal MRI coils using ultimate intrinsic SNR.pdf
Size:
427.57 KB
Format:
Adobe Portable Document Format
Description:
Full printable version