Design of internal MRI coils using ultimate intrinsic SNR
buir.contributor.author | Atalar, Ergin | |
dc.citation.epage | 228 | en_US |
dc.citation.issueNumber | 4 | en_US |
dc.citation.spage | 221 | en_US |
dc.citation.volumeNumber | 22 | en_US |
dc.contributor.author | Eryaman, Y. | en_US |
dc.contributor.author | Öner, Y. | en_US |
dc.contributor.author | Atalar, Ergin | en_US |
dc.date.accessioned | 2016-02-08T10:03:07Z | |
dc.date.available | 2016-02-08T10:03:07Z | |
dc.date.issued | 2009-09-27 | en_US |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.description.abstract | Object: Internal MRI coils have important applications in diagnostic and interventional studies. Since they can be placed very close to the region of interest in the body, they are favored over external coils in applications where high-resolution images are required. In this paper it is demonstrated that ultimate intrinsic SNR (UISNR) and the optimum coil sensitivity solutions can be used to make new coil designs with higher intrinsic SNR. Materials and methods: In this study, UISNR, which is the maximum attainable value of the intrinsic SNR, is used as a measure of performance and as a design criterion. As an example, a novel endorectal MRI coil is designed. The design is tested with phantom and patient studies. Results: An endorectal coil is built to demonstrate the effectiveness of the design strategy. ISNR of the endorectal coil approximates the UISNR to 72%. Conclusion: An internal coil design method that takes advantage of the UISNR and optimum coil sensitivity calculations was presented. This method can also be used to design better internal MRI coils for different applications. | en_US |
dc.description.provenance | Made available in DSpace on 2016-02-08T10:03:07Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2009 | en |
dc.identifier.doi | 10.1007/s10334-009-0167-1 | en_US |
dc.identifier.issn | 0968-5243 | |
dc.identifier.uri | http://hdl.handle.net/11693/22666 | |
dc.language.iso | English | en_US |
dc.publisher | Springer | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1007/s10334-009-0167-1 | en_US |
dc.source.title | Magnetic Resonance Materials in Physics, Biology and Medicine | en_US |
dc.subject | Internal MRI coils | en_US |
dc.subject | Intrinsic SNR | en_US |
dc.subject | Ultimate intrinsic SNR | en_US |
dc.title | Design of internal MRI coils using ultimate intrinsic SNR | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Design of internal MRI coils using ultimate intrinsic SNR.pdf
- Size:
- 427.57 KB
- Format:
- Adobe Portable Document Format
- Description:
- Full printable version