Fast calibration with compressed sensing using alternating direction method of multipliers in magnetic particle imaging
buir.contributor.author | İlbey, Serhat | |
buir.contributor.author | Sarıtaş, Emine Ulkü | |
buir.contributor.author | Top, Can Barıs | |
dc.contributor.author | İlbey, Serhat | en_US |
dc.contributor.author | Sarıtaş, Emine Ulkü | en_US |
dc.contributor.author | Top, Can Barıs | en_US |
dc.coverage.spatial | Istanbul, Turkey | en_US |
dc.coverage.spatial | Istanbul, Turkey | en_US |
dc.date.accessioned | 2019-02-21T16:04:11Z | |
dc.date.available | 2019-02-21T16:04:11Z | |
dc.date.issued | 2018 | en_US |
dc.department | National Magnetic Resonance Research Center (UMRAM) | en_US |
dc.department | Interdisciplinary Program in Neuroscience (NEUROSCIENCE) | en_US |
dc.department | Aysel Sabuncu Brain Research Center (BAM) | en_US |
dc.description | Date of Conference: 24 Nov.-26 Dec. 2017 | en_US |
dc.description | Conference Name:2017 21st National Biomedical Engineering Meeting (BIYOMUT) | en_US |
dc.description.abstract | Magnetic Particle Imaging (MPI) is a new imaging modality that is used for imaging the spatial distribution of superparamagnetic iron oxide nanoparticles injected as tracers. Image reconstruction in MPI can be realized directly in X-space or with a system calibration matrix. It is envisaged that obtaining a system calibration matrix would take days for a field of view of clinical purposes. On the other hand, the need for real-time imaging for applications such as interventional angiography implies that faster and more efficient reconstruction algorithms are needed than the ones at present. In this work, we present rapid system calibration with compressive sensing, and reconstruction results that have higher resolution and contrast with respect to the most common technique, Kaczmarz, using Alternating Direction Method of Multipliers (ADMM). | |
dc.description.provenance | Made available in DSpace on 2019-02-21T16:04:11Z (GMT). No. of bitstreams: 1 Bilkent-research-paper.pdf: 222869 bytes, checksum: 842af2b9bd649e7f548593affdbafbb3 (MD5) Previous issue date: 2018 | en |
dc.identifier.doi | 10.1109/BIYOMUT.2017.8479245 | |
dc.identifier.eisbn | 978-1-5386-5340-1 | |
dc.identifier.uri | http://hdl.handle.net/11693/50167 | |
dc.language.iso | Turkish | |
dc.publisher | IEEE | |
dc.relation.isversionof | https://doi.org/10.1109/BIYOMUT.2017.8479245 | |
dc.source.title | 2017 21st National Biomedical Engineering Meeting (BIYOMUT) | en_US |
dc.title | Fast calibration with compressed sensing using alternating direction method of multipliers in magnetic particle imaging | en_US |
dc.title.alternative | Manyetik parçacık görüntülemede yön değiştiren çarpanlar yöntemi kullanılarak sıkıştırılmış algılamalı hızlı kalibrasyon | en_US |
dc.type | Conference Paper | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Fast_calibration_with_compressed_sensing_using_alternating_direction_method_of_multipliers_in_magnetic_particle_imaging.pdf
- Size:
- 601.46 KB
- Format:
- Adobe Portable Document Format
- Description:
- Full printable version