SNR dependence of optimal parameters for apparent diffusion coefficient measurements
buir.contributor.author | Sarıtaş, Emine Ülkü | |
dc.citation.epage | 437 | en_US |
dc.citation.issueNumber | 2 | en_US |
dc.citation.spage | 424 | en_US |
dc.citation.volumeNumber | 30 | en_US |
dc.contributor.author | Sarıtaş, Emine Ülkü | en_US |
dc.contributor.author | Lee, J. | en_US |
dc.contributor.author | Nishimura, D. | en_US |
dc.date.accessioned | 2020-04-10T10:56:40Z | |
dc.date.available | 2020-04-10T10:56:40Z | |
dc.date.issued | 2011 | |
dc.department | Aysel Sabuncu Brain Research Center (BAM) | en_US |
dc.description.abstract | Optimizing the diffusion-weighted imaging (DWI) parameters (i.e., the b -value and the number of image averages) to the tissue of interest is essential for producing high-quality apparent diffusion coefficient (ADC) maps. Previous investigation of this optimization was performed assuming Gaussian noise statistics for the ADC map, which is only valid for high signal-to-noise ratio (SNR) imaging. In this work, the true statistics of the noise in ADC maps are derived, followed by an optimization of the DWI parameters as a function of the imaging SNR. Specifically, it is demonstrated that the optimum b -value is a monotonically increasing function of the imaging SNR, which converges to the optimum b -value from previously proposed approaches for high-SNR cases, while exhibiting a significant deviation from this asymptote for low-SNR situations. Incorporating the effects of T 2 weighting further increases the SNR dependence of the optimal parameters. The proposed optimization scheme is particularly important for high-resolution DWI, which intrinsically suffers from low SNR and therefore cannot afford the use of the conventional high b -values. Comparison scans were performed for high-resolution DWI of the spinal cord, demonstrating the improvements in the resulting images and the ADC maps achieved by this method. | en_US |
dc.description.provenance | Submitted by Onur Emek (onur.emek@bilkent.edu.tr) on 2020-04-10T10:56:40Z No. of bitstreams: 1 Bilkent-research-paper.pdf: 268963 bytes, checksum: ad2e3a30c8172b573b9662390ed2d3cf (MD5) | en |
dc.description.provenance | Made available in DSpace on 2020-04-10T10:56:40Z (GMT). No. of bitstreams: 1 Bilkent-research-paper.pdf: 268963 bytes, checksum: ad2e3a30c8172b573b9662390ed2d3cf (MD5) Previous issue date: 2011 | en |
dc.identifier.doi | 10.1109/TMI.2010.2084583 | en_US |
dc.identifier.issn | 0278-0062 | |
dc.identifier.uri | http://hdl.handle.net/11693/53594 | |
dc.language.iso | English | en_US |
dc.publisher | IEEE | en_US |
dc.relation.isversionof | https://doi.org/10.1109/TMI.2010.2084583 | en_US |
dc.source.title | IEEE Transactions on Medical Imaging | en_US |
dc.title | SNR dependence of optimal parameters for apparent diffusion coefficient measurements | en_US |