Adaptive reconstruction for vessel preservation in unenhanced MR angiography
dc.citation.epage | 580 | en_US |
dc.citation.spage | 577 | en_US |
dc.contributor.author | Ilıcak, Efe | en_US |
dc.contributor.author | Çetin, S. | en_US |
dc.contributor.author | Sarıtaş, Emine Ülkü | en_US |
dc.contributor.author | Ünal, G. | en_US |
dc.contributor.author | Çukur, Tolga | en_US |
dc.coverage.spatial | Zonguldak, Turkey | en_US |
dc.date.accessioned | 2018-04-12T11:48:45Z | |
dc.date.available | 2018-04-12T11:48:45Z | |
dc.date.issued | 2016 | en_US |
dc.department | Department of Electrical and Electronics Engineering | en_US |
dc.department | National Magnetic Resonance Research Center (UMRAM) | en_US |
dc.description | Date of Conference: 16-19 May 2016 | en_US |
dc.description | Conference Name: IEEE 24th Signal Processing and Communications Applications Conference, SIU 2016 | en_US |
dc.description.abstract | The image quality of unenhanced magnetic resonance angiography, which images blood vessels without contrast agents, is limited by constraints related to scan time. To address this problem, techniques that undersample angiographic data and then apply regularized reconstructions are used. Conventional reconstructions employ regularization terms with uniform spatial weighting. Thus, they can yield improper suppression of aliasing artifacts and poor blood/background contrast. In this study, a reconstruction strategy is evaluated that applies spatially-adaptive regularization based on vessel maps obtained via a tractographic segmentation. This strategy is compared with conventional methods in terms of peak signal to noise ratio, structural similarity and contrast. | en_US |
dc.description.provenance | Made available in DSpace on 2018-04-12T11:48:45Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 179475 bytes, checksum: ea0bedeb05ac9ccfb983c327e155f0c2 (MD5) Previous issue date: 2016 | en |
dc.identifier.doi | 10.1109/SIU.2016.7495806 | en_US |
dc.identifier.uri | http://hdl.handle.net/11693/37711 | |
dc.language.iso | Turkish | en_US |
dc.publisher | IEEE | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1109/SIU.2016.7495806 | en_US |
dc.source.title | Proceedings of the IEEE 24th Signal Processing and Communications Applications Conference, SIU 2016 | en_US |
dc.subject | Magnetic resonance angiography | en_US |
dc.subject | Reconstruction | en_US |
dc.subject | Segmentation | en_US |
dc.subject | Unenhanced | en_US |
dc.subject | Vasculature | en_US |
dc.title | Adaptive reconstruction for vessel preservation in unenhanced MR angiography | en_US |
dc.title.alternative | Kontrast maddesiz anjiyografide damar korunumu için uyarlanmış geriçatım | en_US |
dc.type | Conference Paper | en_US |