The acoustical performance analysis of Bilkent amphitheater: proposal for acoustical renovation

dc.citation.epage178en_US
dc.citation.issueNumber2en_US
dc.citation.spage167en_US
dc.citation.volumeNumber49en_US
dc.contributor.authorSü, Z.en_US
dc.contributor.authorYilmazer, S.en_US
dc.date.accessioned2016-02-08T10:19:16Z
dc.date.available2016-02-08T10:19:16Z
dc.date.issued2006-06en_US
dc.departmentDepartment of Interior Architecture and Environmental Designen_US
dc.description.abstractThe 4000 seat multi-purpose Bilkent Amphitheater is a semi-dosed amphitheater with a volume of 90,000 m3, designed to serve the University's and the city's educational and artistic activities. At the beginning, the amphitheater was designed only for open-air performances. Afterwards it was decided it would be roofed with a tensile membrane in order to protect the spectators from atmospheric effects. However, the covered amphitheater was turned into a resounding and a problematic place widi a reverberation time of more than 6 s. when the hall is unoccupied. Acoustical interventions were implemented, but these have not been sufficient in decreasing the number of problematic echoes and dead spots. This paper analyzes the hall by means of assessing the fundamental acoustical parameters for both speech and music. Parameters such as reverberation time, early decay time, clarify, definition, lateral fraction, strength and speech transmission index were calculated by the aid of ODEON Room Acoustics Program simulation software Version 6.01. It was observed that most of the parameters are out of the optimum range, and that the sound focused strongly in some locations. After further acoustical renovation of the hall, the distribution of sound became more homogenous as measures of most of the parameters fell into reasonable ranges.en_US
dc.description.provenanceMade available in DSpace on 2016-02-08T10:19:16Z (GMT). No. of bitstreams: 1 bilkent-research-paper.pdf: 70227 bytes, checksum: 26e812c6f5156f83f0e77b261a471b5a (MD5) Previous issue date: 2006en
dc.identifier.doi10.3763/asre.2006.4923en_US
dc.identifier.issn0003-8628
dc.identifier.urihttp://hdl.handle.net/11693/23792
dc.language.isoEnglishen_US
dc.publisherTaylor & Francisen_US
dc.relation.isversionofhttps://doi.org/10.3763/asre.2006.4923en_US
dc.source.titleArchitectural Science Reviewen_US
dc.titleThe acoustical performance analysis of Bilkent amphitheater: proposal for acoustical renovationen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The_Acoustical_Performance_Analysis_of_Bilkent_Amphitheater_Proposal_for_Acoustical_Renovation.pdf
Size:
2.24 MB
Format:
Adobe Portable Document Format
Description:
Full printable version