BUIR logo
Communities & Collections
All of BUIR
  • English
  • Türkçe
Log In
Please note that log in via username/password is only available to Repository staff.
Have you forgotten your password?
  1. Home
  2. Browse by Subject

Browsing by Subject "Voltage"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Operation of carbon nanotube thin-film transistors at elevated temperatures
    (IEEE, 2009-12) Öztürk, Sadi; Doğan, Mustafa; Aktaş, Özgür
    The authors study the operation of carbon nanotube thin-film transistors (CNT-TFT) at elevated temperatures. Due to the small bandgap of semiconducting carbon nanotubes, CNT-TFTs are not suitable to be developed as high-temperature devices. However, CNT-TFTs will still have to endure elevated temperatures when employed in large-area and flexible electronic applications. The temperature range that can be expected in these applications is well below 100°C. In this work, the authors demonstrate that even at 100°C, CNT-TFT devices are operational but with a reduced ON/OFF ratio. Beyond 100°C, the ON/OFF ratio degrades rapidly.
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Response of surface acoustic wave imaging systems to cylindrical inhomogeneities
    (IEEE, 1988-10) Gunalp, N.; Baygun, B.; Surucu, F.; Atalar, Abdullah
    The authors present a theory to predict the response of a SAW (surface acoustic wave) imaging system. In particular, they calculate the response to cylindrical cavities as a function of cavity position with respect to the focus point. The calculations indicated a high leak rate material will result in a better resolution in the y-direction. The theory also predicts an enhancement in the received signal level when the cylinder circumference equals the SAW wavelength. The images of cylinders obtained with such systems will indicate the size of the cylinders correctly at 20 dB below peak value as long as the cylinder diameter is larger than about a Rayleigh wavelength. For small cylinders the received peak amplitude can be used to determine the size of the cylinder.

About the University

  • Academics
  • Research
  • Library
  • Students
  • Stars
  • Moodle
  • WebMail

Using the Library

  • Collections overview
  • Borrow, renew, return
  • Connect from off campus
  • Interlibrary loan
  • Hours
  • Plan
  • Intranet (Staff Only)

Research Tools

  • EndNote
  • Grammarly
  • iThenticate
  • Mango Languages
  • Mendeley
  • Turnitin
  • Show more ..

Contact

  • Bilkent University
  • Main Campus Library
  • Phone: +90(312) 290-1298
  • Email: dspace@bilkent.edu.tr

Bilkent University Library © 2015-2025 BUIR

  • Privacy policy
  • Send Feedback