BUIR logo
Communities & Collections
All of BUIR
  • English
  • Türkçe
Log In
Please note that log in via username/password is only available to Repository staff.
Have you forgotten your password?
  1. Home
  2. Browse by Subject

Browsing by Subject "Portable equipment"

Filter results by typing the first few letters
Now showing 1 - 3 of 3
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    ItemOpen Access
    A color-based face tracking algorithm for enhancing interaction with mobile devices
    (Springer, 2010-05) Bulbul, A.; Cipiloglu, Z.; Capin, T.
    A color-based face tracking algorithm is proposed to be used as a human-computer interaction tool on mobile devices. The solution provides a natural means of interaction enabling a motion parallax effect in applications. The algorithm considers the characteristics of mobile useconstrained computational resources and varying environmental conditions. The solution is based on color comparisons and works on images gathered from the front camera of a device. In addition to color comparisons, the coherency of the facial pixels is considered in the algorithm. Several applications are also demonstrated in this work, which use the face position to determine the viewpoint in a virtual scene, or for browsing large images. The accuracy of the system is tested under different environmental conditions such as lighting and background, and the performance of the system is measured in different types of mobile devices. According to these measurements the system allows for accurate (7% RMS error) face tracking in real time (20-100 fps). © Springer-Verlag 2010.
  • Loading...
    Thumbnail Image
    ItemOpen Access
    A face tracking algorithm for user interaction in mobile devices
    (IEEE, 2009-09) Bülbül, Abdullah; Çipiloğlu, Zeynep; Çapin, Tolga
    A new face tracking algorithm, and a human-computer interaction technique based on this algorithm, are proposed for use on mobile devices. The face tracking algorithm considers the limitations of mobile use case - constrained computational resources and varying environmental conditions. The solution is based on color comparisons and works on images gathered from the front camera of a device. The face tracking system generates 2D face position as an output that can be used for controlling different applications. Two of such applications are also presented in this work; the first example uses face position to determine the viewpoint, and the second example enables an intuitive way of browsing large images. © 2009 IEEE.
  • Loading...
    Thumbnail Image
    ItemOpen Access
    A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate
    (Royal Society of Chemistry, 2016) Isiksacan, Z.; Erel, O.; Elbuken, C.
    The erythrocyte sedimentation rate (ESR) is a frequently used 30 min or 60 min clinical test for screening of several inflammatory conditions, infections, trauma, and malignant diseases, as well as non-inflammatory conditions including prostate cancer and stroke. Erythrocyte aggregation (EA) is a physiological process where erythrocytes form face-to-face linear structures, called rouleaux, at stasis or low shear rates. In this work, we proposed a method for ESR measurement from EA. We developed a microfluidic opto-electro-mechanical system, using which we experimentally showed a significant correlation (R2 = 0.86) between ESR and EA. The microfluidic system was shown to measure ESR from EA using fingerprick blood in 2 min. 40 μl of whole blood is filled in a disposable polycarbonate cartridge which is illuminated with a near infrared emitting diode. Erythrocytes were disaggregated under the effect of a mechanical shear force using a solenoid pinch valve. Following complete disaggregation, transmitted light through the cartridge was measured using a photodetector for 1.5 min. The intensity level is at its lowest at complete disaggregation and highest at complete aggregation. We calculated ESR from the transmitted signal profile. We also developed another microfluidic cartridge specifically for monitoring the EA process in real-time during ESR measurement. The presented system is suitable for ultrafast, low-cost, and low-sample volume measurement of ESR at the point-of-care.

About the University

  • Academics
  • Research
  • Library
  • Students
  • Stars
  • Moodle
  • WebMail

Using the Library

  • Collections overview
  • Borrow, renew, return
  • Connect from off campus
  • Interlibrary loan
  • Hours
  • Plan
  • Intranet (Staff Only)

Research Tools

  • EndNote
  • Grammarly
  • iThenticate
  • Mango Languages
  • Mendeley
  • Turnitin
  • Show more ..

Contact

  • Bilkent University
  • Main Campus Library
  • Phone: +90(312) 290-1298
  • Email: dspace@bilkent.edu.tr

Bilkent University Library © 2015-2025 BUIR

  • Privacy policy
  • Send Feedback