Browsing by Subject "Impedance"
Now showing 1 - 6 of 6
- Results Per Page
- Sort Options
Item Open Access Algebraic reconstraction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density(Institute of Physics and Engineering in Medicine, 2004) Ider, Y. Z.; Onart, S.Magnetic resonance-electrical impedance tomography (MREIT) algorithms fall into two categories: those utilizing internal current density and those utilizing only one component of measured magnetic flux density. The latter group of algorithms have the advantage that the object does not have to be rotated in the magnetic resonance imaging (MRI) system. A new algorithm which uses only one component of measured magnetic flux density is developed. In this method, the imaging problem is formulated as the solution of a non-linear matrix equation which is solved iteratively to reconstruct resistivity. Numerical simulations are performed to test the algorithm both for noise-free and noisy cases. The uniqueness of the solution is monitored by looking at the singular value behavior of the matrix and it is shown that at least two current injection profiles are necessary. The method is also modified to handle region-of-interest reconstructions. In particular it is shown that, if the image of a certain xy-slice is sought for, then it suffices to measure the z-component of magnetic flux density up to a distance above and below that slice. The method is robust and has good convergence behavior for the simulation phantoms used.Item Open Access Design and implementation of capacitive micromachined ultrasonic transducers for high power(IEEE, 2011) Yamaner F.Y.; Ölçüm, Selim; Bozkurt, A.; Köymen, Hayrettin; Atalar, AbdullahCapacitive micromachined ultrasonic transducers (CMUTs) have a strong potential to compete piezoelectric transducers in high power applications. In a CMUT, obtaining high port pressure competes with high particle velocity: a small gap is required for high electrostatic force while particle displacement is limited by the gap height. On the other hand, it is shown in [1] that CMUT array exhibits radiation impedance maxima over a relatively narrow frequency band. In this paper, we describe a design approach in which CMUT array elements resonate at the frequency of maximum impedance and have gap heights such that the generated electrostatic force in uncollapsed mode, can sustain particle displacement peak amplitude up to the gap height. The CMUT parameters are optimized for around 3 MHz of operation, using both a SPICE model and FEM. The optimized parameters require a thick membrane and low gap heights to get maximum displacement without collapsing membrane during the operation. We used anodic bonding process to fabricate CMUT arrays. A conductive 100 μm silicon wafer is bonded to a glass wafer. Before the bonding process, the silicon wafer is thermally oxidized to create an insulating layer which prevents break down in the operation. Then, the cavities are formed on the insulating layer by a wet etch. The gap height is set to 100 nm. Meanwhile, the glass wafer is dry etched by 120 nm and the etched area is filled by gold evaporation to create the bottom electrodes. The wafers are dipped into piranha solution and bonding process is done afterwards. The fabricated CMUTs are tested in an oil tank. To eliminate the DC voltage which may cause charging problem in the operation, we tried to drive the CMUT array with large continuous wave signals at half of the operating frequency. We observed 1MPa peak to peak pressure with -23 dB second harmonic at the surface of the array (Fig. 1). The proposed design further extends the operation of CMUTs. Observing low harmonic distortions at high output pressure levels, without any charging problem, make CMUT a big candidate for high power applications. © 2011 IEEE.Item Open Access Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction(Institute of Physics Publishing, 2003) Birgül, Ö.; Eyüboğlu, B. M.; İder, Y. Z.Magnetic resonance electrical impedance tomography (MR-EIT) is an emerging imaging technique that reconstructs conductivity images using magnetic flux density measurements acquired employing MRI together with conventional EIT measurements. In this study, experimental MR-EIT images from phantoms with conducting and insulator objects are presented. The technique is implemented using the 0.15 T Middle East Technical University MRI system. The dc current method used in magnetic resonance current density imaging is adopted. A reconstruction algorithm based on the sensitivity matrix relation between conductivity and only one component of magnetic flux distribution is used. Therefore, the requirement for object rotation is eliminated. Once the relative conductivity distribution is found, it is scaled using the peripheral voltage measurements to obtain the absolute conductivity distribution. Images of several insulator and conductor objects in saline filled phantoms are reconstructed. The L2 norm of relative error in conductivity values is found to be 13%, 17% and 14% for three different conductivity distributions.Item Open Access Impedance-type measurements using XPS(Optical Society of America, 2009) Süzer, Şefik; Abelev, E.; Bernasek, S. L.An impedance type of measurement using X-ray photoelectron spectroscopy is applied for probing charging/discharging dynamics of a sample containing Rb deposited on a SiO(2)/Si substrate containing an octadecyltrichlorosilane (OTS) bilayer coating. The OTS bilayer coatings have possible use as anti-relaxation wall coatings for alkali atom vapor cells in miniaturized instruments such as chip-scale atomic clocks, and/or magnetometers. The measurement consists of the application of bipolar square wave pulses of +/- 10.0 V amplitude to the sample with varying frequencies in the range of 10(-2) to 10(2) Hz while recording X-ray photoemission data. For a conducting sample this type of measurement twins all the photoemission peaks at -10.0 and +10.0 eV positions at all frequencies with exactly 20.0 eV difference between them. However, for samples amenable to charging, the difference between the twinned peaks is less than 20.0 eV, and gradually decreases at correspondingly lower frequencies. For the sample under consideration here at 0.01 Hz, the twinned O1s and Si2p peaks, representing the SiO(2) substrate, are separated by 18.2 eV, displaying a 1.8 eV charging shift. These positions differ from those of the C1s (18.0 eV) representing the OTS bilayer and the Rb3d peaks (18.1 eV). These results reveal that the Rb is electrically (perhaps also chemically) isolated from the OTS bilayer, which may be correlated with the improved performance of the OTS bilayers as anti-relaxation coatings in these alkali atom magnetometer cells.Item Open Access Magnetic resonance electrical impedance tomography (MREIT) based on the solution of the convection equation using FEM with stabilization(Institute of Physics Publishing, 2012-07-27) Oran, O. F.; Ider, Y. Z.Most algorithms for magnetic resonance electrical impedance tomography (MREIT) concentrate on reconstructing the internal conductivity distribution of a conductive object from the Laplacian of only one component of the magnetic flux density (∇ 2B z) generated by the internal current distribution. In this study, a new algorithm is proposed to solve this ∇ 2B z-based MREIT problem which is mathematically formulated as the steady-state scalar pure convection equation. Numerical methods developed for the solution of the more general convectiondiffusion equation are utilized. It is known that the solution of the pure convection equation is numerically unstable if sharp variations of the field variable (in this case conductivity) exist or if there are inconsistent boundary conditions. Various stabilization techniques, based on introducing artificial diffusion, are developed to handle such cases and in this study the streamline upwind Petrov-Galerkin (SUPG) stabilization method is incorporated into the Galerkin weighted residual finite element method (FEM) to numerically solve the MREIT problem. The proposed algorithm is tested with simulated and also experimental data from phantoms. Successful conductivity reconstructions are obtained by solving the related convection equation using the Galerkin weighted residual FEM when there are no sharp variations in the actual conductivity distribution. However, when there is noise in the magnetic flux density data or when there are sharp variations in conductivity, it is found that SUPG stabilization is beneficial.Item Open Access Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging(Wiley-Blackwell Publishing, Inc., 2015) Acikel, V.; Uslubas, A.; Atalar, ErginPurpose: The authors purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (MRI) examination. Methods: In this study, IPG case and electrode are modeled with a voltage source and impedance. Values of these parameters are found using the modified transmission line method (MoTLiM) and the method of moments (MoM) simulations. Once the parameter values of an electrode/IPG case model are determined, they can be connected to any lead, and tip heating can be analyzed. To validate these models, both MoM simulations and MR experiments were used. The induced currents on the leads with the IPG case or electrode connections were solved using the proposed models and the MoTLiM. These results were compared with the MoM simulations. In addition, an electrode was connected to a lead via an inductor. The dissipated power on the electrode was calculated using the MoTLiM by changing the inductance and the results were compared with the specific absorption rate results that were obtained using MoM. Then, MRI experiments were conducted to test the IPG case and the electrode models. To test the IPG case, a bare lead was connected to the case and placed inside a uniform phantom. During a MRI scan, the temperature rise at the lead was measured by changing the lead length. The power at the lead tip for the same scenario was also calculated using the IPG case model and MoTLiM. Then, an electrode was connected to a lead via an inductor and placed inside a uniform phantom. During a MRI scan, the temperature rise at the electrode was measured by changing the inductance and compared with the dissipated power on the electrode resistance. Results: The induced currents on leads with the IPG case or electrode connection were solved for using the combination of the MoTLiM and the proposed lumped circuit models. These results were compared with those from the MoM simulations. The mean square error was less than 9%. During the MRI experiments, when the IPG case was introduced, the resonance lengths were calculated to have an error less than 13%. Also the change in tip temperature rise at resonance lengths was predicted with less than 4% error. For the electrode experiments, the value of the matching impedance was predicted with an error less than 1%. Conclusions: Electrical models for the IPG case and electrode are suggested, and the method is proposed to determine the parameter values. The concept of matching of the electrode to the lead is clarified using the defined electrode impedance and the lead Thevenin impedance. The effect of the IPG case and electrode on tip heating can be predicted using the proposed theory. With these models, understanding the tissue heating due to the implants becomes easier. Also, these models are beneficial for implant safety testers and designers. Using these models, worst case conditions can be determined and the corresponding implant test experiments can be planned.