Browsing by Subject "Heat generation"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Open Access Elimination of catastrophic optical mirror damage in continuous-wave high-power laser diodes using multi-section waveguides(Optica Publishing Group (formerly OSA), 2022-08-29) Liu, Yuxian; Ebadi, Kaveh; Sünnetçioğlu, Ali Kaan; Gündoğdu, Sinan; Şengül, Serdar; Zhao, Yuliang; Lan, Yu; Zhao, Yongming; Yang, Guowen; Demir, AbdullahOne of the persistent obstacles for high-power laser diodes (LDs) has been the catastrophic optical mirror damage (COMD), which limits the operating power level and lifetime of commercial high-power LDs. The output facet of LD reaches a critical temperature resulting in COMD, which is an irreversible device failure. Here, we fabricate multi-section LDs by tailoring the waveguide structure along the cavity that separates the output facet from the heat-generating lasing region. In this method, the LD waveguide is divided into electrically isolated laser and window sections along the cavity. The laser section is pumped at a high current to achieve high output power, and the window is biased at a low current with negligible heat generation. This design restricts the thermal impact of the laser section on the facet, and the window section allows lossless transport of the laser to the output facet. The lasers were operated continuous-wave up to the maximum achievable power. While standard LDs show COMD failures, the multi-section waveguide LDs are COMD-free. Our technique and results provide a pathway for high-reliability LDs, which would find diverse applications in semiconductor lasers. © 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement.Item Open Access Improved dental implant drill durability and performance using heat and wear resistant protective coatings(Academic Press, 2018) Er, N.; Alkan, A.; Ilday, Serim; Bengu, ErmanThe dental implant drilling procedure is an essential step for implant surgery, and frictional heat in bone during drilling is a key factor affecting the success of an implant. The aim of this study was to increase the dental implant drill lifetime and performance by using heat- and wear-resistant protective coatings to decrease the alveolar bone temperature caused by the dental implant drilling procedure. Commercially obtained stainless steel drills were coated with titanium aluminum nitride, diamond-like carbon, titanium boron nitride, and boron nitride coatings via magnetron-sputter deposition. Drilling was performed on bovine femoral cortical bone under the conditions mimicking clinical practice. Tests were performed under water-assisted cooling and under the conditions when no cooling was applied. Coated drill performances and durabilities were compared with those of three commonly used commercial drills with surfaces made from zirconia, black diamond. and stainless steel. Protective coatings with boron nitride, titanium boron nitride, and diamond-like carbon have significantly improved drill performance and durability. In particular, boron nitride-coated drills have performed within safe bone temperature limits for 50 drillings even when no cooling is applied. Titanium aluminium nitride coated drills did not show any improvement over commercially obtained stainless steel drills. Surface modification using heat- and wear-resistant coatings is an easy and highly effective way to improve implant drill performance and durability, which can improve the surgical procedure and the postsurgical healing period. The noteworthy success of different types of coatings is novel and likely to be applicable to various other medical systems.