Browsing by Subject "CSF"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item Open Access Assessment of liliequist membrane by 3D-SPACE technique at 3 T(Springer, 2016) Algın, Oktay; Kılın, M.; Ozmen, E.; Ocakoglu, G.Introduction Liliequist membrane (LM) is the most important anatomic structure for the success of endoscopic third ventriculostomy (ETV). Identification of this membrane is difficult with conventional MRI techniques. The purpose of this retrospective study is to determine the impact of threedimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence with variant flip-angle mode (VFAM) in the assessment of LM at 3-T MRI devices. Methods 3D-SPACE with VFAMimages were obtained in 445 patients. LM visibility and integrity were scored as 0 (good), 1 (moderate), and 2 (poor) on these images for each parts (sellar, diencephalic, and mesencephalic) and overall of the membrane. Results According to the LMoverall integrity scores, 11%(48 cases) of the patients had perforated membrane. According to subsegmental integrity scores, sellar part was completely intact in 63 % of patients, diencephalic segment was completely intact in 60 % of the patients, and mesencephalic segment was completely intact in 95 % of the patients. Visibility scores of the third ventricle inferior wall were significantly higher in the patients with intact LM (p = 0.001). There was not any statistically significant relationship between LM pattern and overall integrity (p = 0.352). LM attachment sites could be detected easier in the patients who had better visibility of third ventricle inferior wall or intact LM (p < 0.001 for both). Conclusion 3D-SPACE technique is a useful alternative for the evaluation of morphology, integrity, individual variations, topographic relationships, and visibility of LM since it has some advantages including lower SAR values, fewer artifacts, and high-resolution images.Item Open Access Cerebrospinal fluid velocity changes of idiopathic scoliosis: a preliminary study on 3-T PC-MRI and 3D-SPACE-VFAM data(Springer, 2021-10-06) Algın, Oktay; Koç, Ural; Yalçın, N.Objectives To the best of our knowledge, there is no study on 3-Tesla (3-T) phase-contrast MRI (PC-MRI) and three-dimensional sampling perfection with application-optimized contrasts using diferent fip-angle evolutions (3D-SPACE-VFAM) in the evaluation of idiopathic scoliosis. This study aimed to investigate CSF abnormalities in the scoliotic spine using 3-T PC MRI and 3D-SPACE-VFAM techniques. Methods Thirty-four patients and 14 controls were examined with spinal PC-MRI and T2-weighted 3D-SPACE-VFAM techniques. Inter- and intra-reader agreements of fow-void phenomenon on 3D-SPACE-VFAM images, and velocity values on PC-MRI data were also evaluated. Results There are statistically signifcant diferences between scoliosis and control groups based on the highest and mean peak velocity values on PC-MRI images (p=0.005 and p=0.023, respectively). The main thoracic (MT) group’s highest peak CSF velocity values were higher than the control group (p=0.022). There is a signifcant diference between the patient and control groups regarding fow-void phenomenon scores on 3D-SPACE-VFAM images (p=0.036). Inter- and intra-reader agreement values related to PC-MRI velocity measurements were perfect for all PC-MRI readings. Inter- and intra-reader agreement values of the fow-void phenomenon scores were moderate. Conclusions Our study has led us to conclude that idiopathic scoliosis is associated with CSF fow disturbances in parallel with the literature. MRI can demonstrate these abnormalities in a non-invasive and radiation-free way.Item Open Access Evaluation of hydrocephalus patients with 3D-SPACE technique using variant FA mode at 3T(Springer, 2018) Algin, O.The major advantages of three-dimensional sampling perfection with application optimized contrasts using different flip-angle evolution (3D-SPACE) technique are its high resistance to artifacts that occurs as a result of radiofrequency or static field, the ability of providing images with sub-millimeter voxel size which allows obtaining reformatted images in any plane due to isotropic three-dimensional data with lower specific absorption rate values. That is crucial during examination of cerebrospinal-fluid containing complex structures, and the acquisition time, which is approximately 5 min for scanning of entire cranium. Recent data revealed that T2-weighted (T2W) 3D-SPACE with variant flip-angle mode (VFAM) imaging allows fast and accurate evaluation of the hydrocephalus patients during both pre- and post-operative period for monitoring the treatment. For a better assessment of these patients; radiologists and neurosurgeons should be aware of the details and implications regarding to the 3D-SPACE technique, and they should follow the updates in this field. There could be a misconception about the difference between T2W-VFAM and routine heavily T2W 3D-SPACE images. T2W 3D-SPACE with VFAM imaging is only a subtype of 3D-SPACE technique. In this review, we described the details of T2W 3D-SPACE with VFAM imaging and comprehensively reviewed its recent applications.Item Open Access Segmentation of spinal subarachnoid lumen with 3d attention u-net(World Scientific Publishing, 2023-05-01) Keleş, A.; Algın, Oktay; Özışık Akdemir, P.; Şen, B.; Çelebi, F. V.Phase Contrast Magnetic Resonance Image (PC-MRI) is an emerging noninvasive technique that contains pulsatile information by measuring the parameters of cerebrospinal fluid (CSF) flow. As CSF flow quantities are measured from the selected region on the images, the accuracy in the identification of the interested region is the most essential, and the examination requires a lot of time and experience to analyze and for accurate CSF flow assessment. In this study, a three-dimensional (3D)-Unet architecture, including pulsatile flow data as the third dimension, is proposed to address the issue. The dataset contains 2176 phase and rephase images from 57 slabs of 39 3-tesla PC-MRI subjects collected from the lower thoracic levels of control and Idiopathic Scoliosis (IS) patients. The procedure starts with labeling the CSF containing spaces in the spinal canal. In the preprocessing step, unequal cardiac cycle images (i.e., frame) and the numbers of MRIs in cases are adjusted by interpolation to align the temporal dimension of the dataset to an equal size. The five-fold cross-validation procedure is used to evaluate the 3D Attention-U-Net model after training and achieved an average weighted performance of 97% precision, 95% recall, 98% F1 score, and 95% area under curve. The success of the model is also measured using the CSF flow waveform quantities as well. The mean flow rates through the labeled and predicted CSF lumens have a significant correlation coefficient of 0.96, and the peak CSF flow rates have a coefficient of 0.65. To our knowledge, this is the first fully automatic 3D deep learning architecture implementation to segment spinal CSF-containing spaces that utilizes both spatial and pulsatile information in PC-MRI data. We expect that our work will attract future research on the use of PC-MRI temporal information for training deep models.