Aysel Sabuncu Brain Research Center (BAM)
Permanent URI for this communityhttps://hdl.handle.net/11693/115575
Browse
Browsing Aysel Sabuncu Brain Research Center (BAM) by Subject "3D-SPACE"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item Open Access Assessment of liliequist membrane by 3D-SPACE technique at 3 T(Springer, 2016) Algın, Oktay; Kılın, M.; Ozmen, E.; Ocakoglu, G.Introduction Liliequist membrane (LM) is the most important anatomic structure for the success of endoscopic third ventriculostomy (ETV). Identification of this membrane is difficult with conventional MRI techniques. The purpose of this retrospective study is to determine the impact of threedimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence with variant flip-angle mode (VFAM) in the assessment of LM at 3-T MRI devices. Methods 3D-SPACE with VFAMimages were obtained in 445 patients. LM visibility and integrity were scored as 0 (good), 1 (moderate), and 2 (poor) on these images for each parts (sellar, diencephalic, and mesencephalic) and overall of the membrane. Results According to the LMoverall integrity scores, 11%(48 cases) of the patients had perforated membrane. According to subsegmental integrity scores, sellar part was completely intact in 63 % of patients, diencephalic segment was completely intact in 60 % of the patients, and mesencephalic segment was completely intact in 95 % of the patients. Visibility scores of the third ventricle inferior wall were significantly higher in the patients with intact LM (p = 0.001). There was not any statistically significant relationship between LM pattern and overall integrity (p = 0.352). LM attachment sites could be detected easier in the patients who had better visibility of third ventricle inferior wall or intact LM (p < 0.001 for both). Conclusion 3D-SPACE technique is a useful alternative for the evaluation of morphology, integrity, individual variations, topographic relationships, and visibility of LM since it has some advantages including lower SAR values, fewer artifacts, and high-resolution images.Item Open Access Cerebrospinal fluid velocity changes of idiopathic scoliosis: a preliminary study on 3-T PC-MRI and 3D-SPACE-VFAM data(Springer, 2021-10-06) Algın, Oktay; Koç, Ural; Yalçın, N.Objectives To the best of our knowledge, there is no study on 3-Tesla (3-T) phase-contrast MRI (PC-MRI) and three-dimensional sampling perfection with application-optimized contrasts using diferent fip-angle evolutions (3D-SPACE-VFAM) in the evaluation of idiopathic scoliosis. This study aimed to investigate CSF abnormalities in the scoliotic spine using 3-T PC MRI and 3D-SPACE-VFAM techniques. Methods Thirty-four patients and 14 controls were examined with spinal PC-MRI and T2-weighted 3D-SPACE-VFAM techniques. Inter- and intra-reader agreements of fow-void phenomenon on 3D-SPACE-VFAM images, and velocity values on PC-MRI data were also evaluated. Results There are statistically signifcant diferences between scoliosis and control groups based on the highest and mean peak velocity values on PC-MRI images (p=0.005 and p=0.023, respectively). The main thoracic (MT) group’s highest peak CSF velocity values were higher than the control group (p=0.022). There is a signifcant diference between the patient and control groups regarding fow-void phenomenon scores on 3D-SPACE-VFAM images (p=0.036). Inter- and intra-reader agreement values related to PC-MRI velocity measurements were perfect for all PC-MRI readings. Inter- and intra-reader agreement values of the fow-void phenomenon scores were moderate. Conclusions Our study has led us to conclude that idiopathic scoliosis is associated with CSF fow disturbances in parallel with the literature. MRI can demonstrate these abnormalities in a non-invasive and radiation-free way.Item Open Access Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3 T MR imaging: preliminary results with variant flip-angle mode(Elsevier, 2013) Algın, Oktay; Turkbey, B.; Ozmen, E.; Ocakoglu, G.; Karaoglanoglu, M.; Arslan, H.Purpose This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STV) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI). Methods PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STV as well as in 10 control cases. The presence of STV was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared. Results There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r] = 0.784; P = 0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STV scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1). Conclusion 3D-SPACE can provide morphological–physiological information for the evaluation of STV with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus.Item Open Access Feasibility of 3-dimensional sampling perfection with application optimized contrast sequence in the evaluation of patients with hydrocephalus(Lippincott Williams and Wilkins, 2015) Kartal, M. G.; Ocakoglu, G.; Algın, OktayPurpose This study aimed to investigate the effectiveness and additive value of T2W 3-dimensional sampling perfection with application optimized contrast (3D-SPACE) with variant flip-angle mode in imaging of all types of hydrocephalus. Our secondary objective was to assess the reliability of 3D-SPACE sequence and correspondence of the results with phase-contrast magnetic resonance imaging (PC-MRI)-based data. Materials and Methods Forty-one patients with hydrocephalus have undergone 3-T MRI. T2W 3D-SPACE sequence has been obtained in addition to routine hydrocephalus protocol. Cerebrospinal fluid circulation, presence/type/etiology of hydrocephalus, obstruction level scores, and diagnostic levels of confidence were evaluated separately by 2 radiologists. In the first session, routine sequences with PC-MRI were evaluated, and in another session, only 3D-SPACE and 3-dimensional magnetization prepared rapid acquisition gradient echo sequences were evaluated. Results obtained in these sessions were compared with each other and those obtained in consensus session. Results Agreement values were very good for both 3D-SPACE and PC-MRI sequences (P < 0.001 for all). Also, the correlation of more experienced reader's 3D-SPACE-based scores and consensus-based scores was perfect (κ = 1, P < 0.001).The mean value of PC-MRI-based confidence scores were lower than those obtained in 3D-SPACE and consensus sessions. Conclusions T2W 3D-SPACE sequence provides morphologic cerebrospinal fluid flow data. It is a noninvasive technique providing extensive multiplanar reformatted images with a lower specific absorption rate. These advantages over PC-MRI make 3D-SPACE sequence a promising tool in management of patients with hydrocephalus. © 2015 Wolters Kluwer Health, Inc.