Modeling of radio frequency induced currents on lead wires during MR imaging using a modified transmission line method (MoTLiM)

buir.advisorAtalar, Ergin
dc.contributor.authorAçıkel, Volkan
dc.date.accessioned2016-01-08T18:13:59Z
dc.date.available2016-01-08T18:13:59Z
dc.date.issued2010
dc.departmentDepartment of Electrical and Electronics Engineeringen_US
dc.descriptionAnkara : The Department of Electrical and Electronics Engineering and the Institute of Engineering and Sciences of Bilkent University, 2010.en_US
dc.descriptionThesis (Master's) -- Bilkent University, 2010.en_US
dc.descriptionIncludes bibliographical references leaves 36-38.en_US
dc.description.abstractMagnetic resonance imaging (MRI) is widely used diagnosis technique. During MRI radio frequency (RF) fields are utilized to excite the spins. If these RF fields incidence on metallic implants, currents will be induce on the metallic parts of implants. Inside the body these induced currents on metallic implants cause heating of tissue and sometimes cause severe burning of tissue. This phenomena makes MRI hazardous for patients with metallic implants. Much work has been done to understand this phenomena. However, most of these work based on purely experimental or numerical methods. So to understand and to obtain a good intuition on this problem a lot of cases must be solved computationally or tested experimentally. In this study lumped element model of the transmission line is modified in order to model the conductive wires of implants inside the body. This model is based on the similarity between the damped oscillatory behavior of transmission line currents and induced currents on wires inside the body. A voltage source is added to model the effect of the incident electric field. Voltages and currents on a infinitesimally small portion of wire are solved. Solving currents and voltages simultaneously on the modified lumped element model lead to a non-homogeneous differential equation for the current. The solution of this differential equation gives the analytical solution for the induced current on the implant lead. To test the validity of this solution, wire under the uniform incident electric field is solved with the Modified Transmission Line Method (MoTLiM) and compared to Methods of Moment (MoM) solution. The results are also verified using phantom experiments. For experimental verification, the distorted flip angle distribution due to induced currents are measured using flip angle imaging techniques. In addition to this, the flip angle distribution around the wire is calculated using results obtained from MoTLiM. Finally these results are compared and an error analysis is carried out.en_US
dc.description.degreeM.S.en_US
dc.description.statementofresponsibilityAçıkel, Volkanen_US
dc.format.extentxiii, 38 leaves, illustrationsen_US
dc.identifier.urihttp://hdl.handle.net/11693/15136
dc.language.isoEnglishen_US
dc.publisherBilkent Universityen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMRIen_US
dc.subjectRF Heatingen_US
dc.subjectInduced currentsen_US
dc.subjectRFen_US
dc.subjectImplant safetyen_US
dc.subject.lccWN185 .A35 2010en_US
dc.subject.lcshMagnetic resonance imaging--Safety measures.en_US
dc.subject.lcshMagnetic resonance imaging--Physiological effects.en_US
dc.subject.lcshRadio frequency identification systems.en_US
dc.titleModeling of radio frequency induced currents on lead wires during MR imaging using a modified transmission line method (MoTLiM)en_US
dc.typeThesisen_US