Modeling of NC-AFM experiments by the utilization of molecular dynamics and the harmonic oscillator model

buir.advisorBaykara, Mehmet Zeyyad
dc.contributor.authorUluutku, Berkin
dc.date.accessioned2017-07-28T12:51:54Z
dc.date.available2017-07-28T12:51:54Z
dc.date.copyright2017-07
dc.date.issued2017-07
dc.date.submitted2017-07-28
dc.departmentDepartment of Mechanical Engineeringen_US
dc.descriptionCataloged from PDF version of article.en_US
dc.descriptionThesis (M.S.): Bilkent University, Department of Mechanical Engineering, İhsan Doğramacı Bilkent University, 2017.en_US
dc.descriptionIncludes bibliographical references (leaves 67-72).en_US
dc.description.abstractAtomic force microscopy is a widely-used instrument in nanotechnology and nanoscience. Imaging of single molecules, atoms or even bond structures and tip-sample interactions with pm and pN resolution are made possible with non-contact atomic force microscope (NC-AFM) techniques. Since very high resolution imaging is relatively recent and underlying effects are not yet fully understood, interpretation of images can be controversial and may differ. Therefore theoretical modeling is used alongside with experimental work in order to gain a better insight about underlying physical phenomena regarding NC-AFM images and related artifacts. In this thesis work, a simulator for NC-AFM experiments is suggested which utilizes the harmonic oscillator equations for AFM cantilever dynamics and molecular dynamics (MD) for the interaction between tip and sample. For this purpose, a model graphene surface with underlying platinum substrate and a platinum tip is created and their interaction is mapped at different distances with MD techniques. Calculated interaction forces are fitted to polynomials and imported to the harmonic oscillator model. With the harmonic oscillator model and imported interaction data, two different operating modes of NC-AFM are modeled: Constant Height and Topography Scan.When obtained force maps are investigated, tip asymmetry related artifacts are observed. Due to tip asymmetry, a shift in detected atom positions and overall spatial disturbance are observed. Furthermore, the mobility of atoms causes elongation of the tip and a bumpy formation of the sample surface near the tip. Elongation of the tip decreased the overall interaction due to increasing sharpness of the tip. Also an overall noise is detected due to individual, thermally-induced movements of atoms. Obtained NC-AFM scan results were able to map the surface as desired. In constant height mode, more attractive hollow-site regions of graphene are detected via high frequency shifts, as expected. Also due to increasing interaction, closer tip-surface distances resulted in higher frequency shifts. Increasing oscillation amplitudes caused a decrease in the ratio of short-range interactions over the whole oscillation cycle and hence decreased the frequency shift. In the topography scan mode, attractive hollow-site regions are tracked as expected; increasing the set frequency shift also increased the topography corrugation and decreased the mean tip-sample distance. Moreover, non-optimal (too slow or too fast) distance controllers resulted in tracking the surface in an unreliable way and controller-induced noise. With these results, a functional NC- AFM model is demonstrated which is able to satisfactorily simulate NC-AFM experiments.en_US
dc.description.degreeM.S.en_US
dc.description.statementofresponsibilityby Berkin Uluutku.en_US
dc.format.extentxvi, 72 leaves : illustrations (some color), charts ; 29 cmen_US
dc.identifier.itemidB156064
dc.identifier.urihttp://hdl.handle.net/11693/33517
dc.language.isoEnglishen_US
dc.publisherBilkent Universityen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNanotechnologyen_US
dc.subjectNanoscienceen_US
dc.subjectNon-contact Atomic Force Microscopeen_US
dc.subjectMolecular Dynamicsen_US
dc.subjectHarmonic Oscillator Modelen_US
dc.titleModeling of NC-AFM experiments by the utilization of molecular dynamics and the harmonic oscillator modelen_US
dc.title.alternativeMoleküler dinamik ve harmonik osilatör modelinin kullanımıyla temassız AKM deneylerinin modellenmesien_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10158520.pdf
Size:
4.91 MB
Format:
Adobe Portable Document Format
Description:
Full printable version
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: