Detection of intramural fat accumulation by 3D-dixon-caipirinha-vibe and the contribution of this technique to the determination of the chronicity of Chron's disease

Date
2021-10-16
Editor(s)
Advisor
Supervisor
Co-Advisor
Co-Supervisor
Instructor
Source Title
Magnetic Resonance Imaging
Print ISSN
0730-725X
Electronic ISSN
1873-5894
Publisher
Elsevier Inc.
Volume
85
Issue
Pages
93 - 101
Language
English
Journal Title
Journal ISSN
Volume Title
Series
Abstract

Objectives In this study; we aimed to evaluate the efficacy of the 3D-Dixon-Caipirinha-Vibe fat images in detecting intramural fat accumulation (IFA) and contributions of 3D-Dixon-Caipirinha-Vibe in the management of patients with Chron's disease. Methods Eighty-five patients who had a 3-tesla MR enterography (MRE) with the 3D-Dixon-Caipirinha-Vibe technique were included. Wall thickness, ADC-value, intramural edema, presence/extension of IFA, and contrast-material enhancement of the affected segments were examined. Findings of MRE were compared statistically with clinical, laboratory, endoscopy, and pathological exams. Results The presence of IFA was more common in patients with chronic active and chronic inflammation than only active inflammation and normal cases. Patients with IFA had a longer disease duration than patients without IFA. IFA-containing segment lengths of patients with chronic active inflammation and chronic inflammation were found to be longer than those with active inflammation. It was found that patients whose pathology results were reported as active inflammation contained less IFA than patients with chronic inflammation. Conclusions The presence of IFA is strongly related to chronicity. 3D-Dixon-Caipirinha-Vibe is a fast, easy, and useful method for detecting IFA and evaluating Chron's disease.

Course
Other identifiers
Book Title
Citation
Published Version (Please cite this version)