Accelerated phase-cycled SSFP imaging with compressed sensing
(Institute of Electrical and Electronics Engineers Inc., 2015)Balanced steady-state free precession (SSFP) imaging suffers from irrecoverable signal losses, known as banding artifacts, in regions of large B0 field inhomogeneity. A common solution is to acquire multiple phase-cycled ... -
Adaptive polyphase subband decomposition structures for image compression
(IEEE, 2000)Subband decomposition techniques have been extensively used for data coding and analysis. In most filter banks, the goal is to obtain subsampled signals corresponding to different spectral regions of the original data. ... -
Algebraic reconstraction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density
(Institute of Physics and Engineering in Medicine, 2004)Magnetic resonance-electrical impedance tomography (MREIT) algorithms fall into two categories: those utilizing internal current density and those utilizing only one component of measured magnetic flux density. The latter ... -
Assessment of information redundancy in ECG signals
(IEEE, 1997-09)In this paper, the morphological information redundancy in standard 12 lead ECG channels is studied. Study is based on decomposing the ECG channels into orthogonal channels by an SVD based algorithm and then reconstructing ... -
Autofocused spotlight SAR image reconstruction of off-grid sparse scenes
(Institute of Electrical and Electronics Engineers Inc., 2017)Synthetic aperture radar (SAR) has significant role in remote sensing. Phase errors due to uncompensated platform motion, measurement model mismatch, and measurement noise can cause degradations in SAR image reconstruction. ... -
Automated image reconstruction for non-cartesian magnetic particle imaging
(Bilkent University, 2019-09)Magnetic particle imaging (MPI) is a high-contrast imaging modality that images the spatial distribution of superparamagnetic iron oxide (SPIO) nanoparticles by exploiting their nonlinear response. In MPI, image ... -
Automatic detection of compound structures by joint selection of region groups from a hierarchical segmentation
(Institute of Electrical and Electronics Engineers, 2016)A challenging problem in remote sensing image analysis is the detection of heterogeneous compound structures such as different types of residential, industrial, and agricultural areas that are composed of spatial arrangements ... -
Bilgisayarlı iyonosfer tomografisinde açılım işlevlerinin ve yeniden yapılandırma algoritmalarının model üzerinden karşılaştırılması
(IEEE, 2005-05)Bilgisayarlı İyonosfer Tomografisi (BİT), iyonosfer elektron yoğunluğunun iki boyutlu veya üç boyutlu olarak görüntülenmesi için kullanılan bir yöntemdir. Bu yöntem özellikle iyonosfer fiziği veya uydu haberleşmesi gibi ... -
Binary morphological subband decomposition for image coding
(IEEE, 1996)In this paper a binary waveform coding method based on morphological subband decomposition coupled with embedded zero-tree and entropy coding is described. This method can be utilized in text compression or bit-plane coding ... -
Coded scenes for fast system calibration in magnetic particle imaging
(IEEE, 2018)Magnetic nanoparticle (MNP) agents have a wide range of clinical application areas for both imaging and therapy. MNP distribution inside the body can be imaged using Magnetic Particle Imaging (MPI). For MPI image reconstruction ... -
Compressed multi-contrast magnetic resonance image reconstruction using Augmented Lagrangian Method
(IEEE, 2016)In this paper, a Multi-Channel/Multi-Contrast image reconstruction algorithm is proposed. The method, which is based on the Augmented Lagrangian Method uses joint convex objective functions to utilize the mutual information ... -
Computation of holographic patterns between tilted planes
(SPIE - International Society for Optical Engineering, 2006-05)Computation of the diffraction pattern that gives the desired reconstruction of an object upon proper illumination is an important process in computer generated holography. A fast computational method, based on the plane ... -
Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns
(Institute of Physics Publishing, 2003)Conventional injected-current electrical impedance tomography (EIT) and magnetic resonance imaging (MRI) techniques can be combined to reconstruct high resolution true conductivity images. The magnetic flux density ... -
DC shift based image reconstruction for magnetic particle imaging
(IEEE, 2017)Magnetic Particle Imaging (MPI) is a new imaging technology that images the spatial distribution of iron oxide nanoparticles. Since the magnetic field strength that can be safely applied in MPI is limited, the field-of-view ... -
Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction
(Institute of Physics Publishing, 2003)Magnetic resonance electrical impedance tomography (MR-EIT) is an emerging imaging technique that reconstructs conductivity images using magnetic flux density measurements acquired employing MRI together with conventional ... -
Human action recognition using distribution of oriented rectangular patches
(Springer, 2007-10)We describe a "bag-of-rectangles" method for representing and recognizing human actions in videos. In this method, each human pose in an action sequence is represented by oriented rectangular patches extracted over the ... -
Image denoising using adaptive subband decomposition
(IEEE, 2001)In this paper, we present a new image denoising method based on adaptive subband decomposition (or adaptive wavelet transform) in which the filter coefficients are updated according to an Least Mean Square (LMS) type ... -
Image reconstruction for Magnetic Particle Imaging using an Augmented Lagrangian Method
(IEEE, 2017)Magnetic particle imaging (MPI) is a relatively new imaging modality that images the spatial distribution of superparamagnetic iron oxide nanoparticles administered to the body. In this study, we use a new method based on ... -
Inertial imaging with nanomechanical systems
(Nature Publishing Group, 2015)Mass sensing with nanoelectromechanical systems has advanced significantly during the last decade. With nanoelectromechanical systems sensors it is now possible to carry out ultrasensitive detection of gaseous analytes, ... -
Linear/nonlinear adaptive polyphase subband decomposition structures for image compression
(IEEE, 1998-05)Subband decomposition techniques have been extensively used for data coding and analysis. In most filter banks, the goal is to obtain subsampled signals corresponding to different spectral bands of the original data. ...