Khan, M.Khan, T. M.Taşdelen, A. S.Yılmaz, MehmetAtalar, AbdullahKöymen, Hayrettin2018-08-102018-08-102018-07-281057-7157http://hdl.handle.net/11693/47737We propose an airborne collapse capacitive micromachined ultrasonic transducer (CMUT) as a practical viable ultrasound transducer capable of providing a stable performance at the off-resonance frequencies. Traditional practice is to bias the CMUT plate close to collapse voltage to achieve high coupling coefficient and sense the incoming ultrasound as an open-circuit receive voltage signal of the transducer or short-circuit receive current (SCRC). Maintaining CMUT plate in the vicinity of collapse threshold is rather difficult. In this paper, an analytic approach to design an airborne collapsed-mode CMUT for maximum off-resonance sensitivity is presented. We use small-signal circuit model to evaluate the performance of a collapsed CMUT for varying operating conditions. CMUT operational parameters that yield the highest off-resonance SCRC are directly obtained from performance design curves. Collapsed CMUT plate is then biased in a critical biasing region that produces a stable and maximum off-resonance sensitivity. We experimentally verify and measure a stable sensitivity of a fabricated collapsed CMUT cell of -60 dB V/Pa at 100 kHz when biased between 50 to 65 V. We characterize our linear circuit model performance against the measured performance of collapsed CMUT in air within 4-dB tolerance. [2018-0058]EnglishCMUTCollapsed CMUT sensitivityCritical biasing regionOff-resonanceSmall-signal circuit modelOptimization of a collapsed mode CMUT receiver for maximum off-resonance sensitivityArticle10.1109/JMEMS.2018.2857444