Browsing by Author "Oto, C."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Reduction of the radiofrequency heating of metallic devices using a dual‐drive birdcage coil(Wiley, 2013) Eryaman, Yiğitcan; Türk, Esra Abacı; Oto, C.; Algin, O.; Atalar, ErginIn this work, it is demonstrated that a dual-drive birdcage coil can be used to reduce the radiofrequency heating of metallic devices during magnetic resonance imaging. By controlling the excitation currents of the two channels of a birdcage coil, the radiofrequency current that is induced near the lead tip could be set to zero. To monitor the current, the image artifacts near the lead tips were measured. The electric field distribution was controlled using a dual-drive birdcage coil. With this method, the lead currents and the lead tip temperatures were reduced substantially [<0.3°C for an applied 4.4 W/kg SAR compared to >4.9°C using quadrature excitation], as demonstrated by phantom and animal experiments. The homogeneity of the flip angle distribution was preserved, as shown by volunteer experiments. The normalized root-mean-square error of the flip angle distribution was less than 10% for all excitations. The average specific absorption rate increased as a trade-off for using different excitation patterns. Copyright © 2012 Wiley Periodicals, Inc.Item Open Access A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI(John Wiley and Sons, 2018) Silemek, B.; Açıkel, V.; Oto, C.; Alipour, A.; Aykut, Z. G.; Algın, O.; Atalar, ErginPurpose: To introduce a temperature sensor implant (TSI) that mimics an active implantable medical device (AIMD) for animal testing of MRI heating. Computer simulations and phantom experiments poorly represent potential temperature increases. Animal experiments could be a better model, but heating experiments conducted immediately after the surgery suffer from alterations of the thermoregulatory and tissue properties during acute testing conditions. Therefore, the aim of this study was to introduce a temperature sensor implant that mimics an AIMD and capable of measuring the electrode temperature after implantation of the device without any further intervention at any time after the surgery in an animal model. Methods: A battery-operated TSI, which resembled an AIMD, was used to measure the lead temperature and impedance and the case temperature. The measured values were transmitted to an external computer via a low-power Bluetooth communication protocol. In addition to validation experiments on the phantom, a sheep experiment was conducted to test the feasibility of the system in subacute conditions. Results: The measurements had a maximum of 0.5°C difference compared to fiber-optic temperature probes. In vivo animal experiments demonstrated feasibility of the system. Conclusion: An active implant, which can measure its own temperature, was proposed to investigate implant heating during MRI examinations. Magn Reson Med 79:2824-2832, 2018.