Selection of the best proper DC-SQUIDs in a multi-SQUID configuration

Date
2007
Editor(s)
Advisor
Supervisor
Co-Advisor
Co-Supervisor
Instructor
Source Title
IEEE Transactions on Applied Superconductivity
Print ISSN
1051-8223
Electronic ISSN
Publisher
IEEE
Volume
17
Issue
2
Pages
680 - 682
Language
English
Journal Title
Journal ISSN
Volume Title
Series
Abstract

We have carried out experimental investigation of multi-DC-SQUID magnetometer configuration fabricated on YBa2Cu30 7-δ thin films onto 24 degree SrTiO3 bicrystal substrates by directly coupling the pick-up loop to DC-SQUIDs. The layout of the magnetometer pick-up loop was chosen as a square washer configuration by maximizing loop effective area and minimizing loop inductance. We have used De-Magnetron Sputtering technique for deposition of the films and chemical etching process for patterning the Josephson junctions having 4 μm widths. The use of multi-SQUID configuration is related to the selection of the best proper junctions for SQUID to improve the chip sensitivity with selectivity option of choosing the squid junctions rather than multichannel operation. Selection of the best junctions compared to each other depending on the junction critical currents and noise levels caused by the fabrication process and placements of the junctions on the grain boundary enable having an increased output signal of the DC-SQUID.