      Design of internal MRI coils using ultimate intrinsic SNR

      Thumbnail
      View / Download
      427.6 Kb
      Author
      Eryaman, Y.
      Öner, Y.
      Atalar, Ergin
      Date
      2009-09-27
      Source Title
      Magnetic Resonance Materials in Physics, Biology and Medicine
      Print ISSN
      0968-5243
      Publisher
      Springer
      Volume
      22
      Issue
      4
      Pages
      221 - 228
      Language
      English
      Type
      Article
      Item Usage Stats
      104
      views
      105
      downloads
      Abstract
      Object: Internal MRI coils have important applications in diagnostic and interventional studies. Since they can be placed very close to the region of interest in the body, they are favored over external coils in applications where high-resolution images are required. In this paper it is demonstrated that ultimate intrinsic SNR (UISNR) and the optimum coil sensitivity solutions can be used to make new coil designs with higher intrinsic SNR. Materials and methods: In this study, UISNR, which is the maximum attainable value of the intrinsic SNR, is used as a measure of performance and as a design criterion. As an example, a novel endorectal MRI coil is designed. The design is tested with phantom and patient studies. Results: An endorectal coil is built to demonstrate the effectiveness of the design strategy. ISNR of the endorectal coil approximates the UISNR to 72%. Conclusion: An internal coil design method that takes advantage of the UISNR and optimum coil sensitivity calculations was presented. This method can also be used to design better internal MRI coils for different applications.
      Keywords
      Internal MRI coils
      Intrinsic SNR
      Ultimate intrinsic SNR
      Permalink
      http://hdl.handle.net/11693/22666
      Published Version (Please cite this version)
      http://dx.doi.org/10.1007/s10334-009-0167-1
      Collections
      • Department of Electrical and Electronics Engineering 3524
      Show full item record

      Browse

      All of BUIRCommunities & CollectionsTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartmentsThis CollectionTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartments

      My Account

      Login

      Statistics

      View Usage StatisticsView Google Analytics Statistics

      Bilkent University

      If you have trouble accessing this page and need to request an alternate format, contact the site administrator. Phone: (312) 290 1771
      Copyright © Bilkent University - Library IT

      Contact Us | Send Feedback | Off-Campus Access | Admin | Privacy