      A new detection method for capacitive micromachine ultrasonic transducers 

      Ergun, A. S.; Temelkuran, B.; Özbay, Ekmel; Atalar, Abdullah (IEEE, 2001)
      Capacitive micromachine ultrasonic transducers (cMUT) have become an alternative to piezoelectric transducers in the past few years. They consist of many small circular membranes that are connected in parallel. In this ...
      Thumbnail

      An equivalent circuit for collapse operation mode of CMUTs 

      Olcum, Selim; Yamaner F.Y.; Bozkurt, A.; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2010)
      Collapse mode of operation of the capacitive mi-cromachined ultrasonic transducers (CMUTs) was shown to be a very effective way for achieving high output pressures. However, no accurate model exists for understanding the ...
      Thumbnail

      Wafer bonded capacitive micromachined underwater transducers 

      Olcum, Selim; Oǧuz, Kaan; Şenlik, Muhammed N.; Yamaner F. Y.; Bozkurt, A.; Atalar, Abdullah; Köymen, Hayrettin (IEEE, 2009-09)
      In this work we have designed, fabricated and tested CMUTs as underwater transducers. Single CMUT membranes with three different radii and 380 microns of thickness are fabricated for the demonstration of an underwater CMUT ...
      Thumbnail

      Radiation impedance of an array of circular capacitive micromachined ultrasonic transducers 

      Senlik, M. N.; Olcum, S.; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2010)
      The radiation impedance of a capacitive micromachined ultrasonic transducer (cMUT) with a circular membrane is calculated analytically using its velocity profile for the frequencies up to its parallel resonance frequency ...
      Thumbnail

      Radiation impedance and equivalent circuit for immersed CMUT array element 

      Şenlik, Muhammed N.; Atalar, Abdullah; Köymen, Hayrettin; Olcum, Selim (IEEE, 2006-10)
      In this paper, we present equivalent circuit for immersed capacitive micromachined ultrasonic transducers (cMUT), based on an accurate parametric model. We also present an accurate approximation for the radiation impedance ...
      Thumbnail

      Experimental characterization of capacitive micromachined ultrasonic transducers 

      Ölçüm, Selim; Atalar, Abdullah; Köymen, Hayrettin; Oğuz, Kağan; Şenlik, Muhammed N. (IEEE, 2007)
      In this paper, capacitive micromachined ultrasonic transducers are fabricated using a sacrificial surface micromachining process. A testing procedure has been established in order to measure the absolute transmit and receive ...
      Thumbnail

      Bandwidth, power and noise considerations in airborne cMUTs 

      Şenlik, Muhammed N.; Olcum, Selim; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2009-09)
      Capacitive micromachined ultrasonic transducers (cMUTs) offer wider bandwidth in air due to their low mechanical impedances. The impedance mismatch between the air and transducer decreases with the smaller device dimensions ...
      Thumbnail

      Interaction between a cMUT cell and a liquid medium around the parallel resonance frequency 

      Şenlik, Muhammed N.; Atalar, Abdullah; Olçum, Selim (IEEE, 2007-10)
      In this paper, we present how a capacitive micromachined ultrasonic transducer (cMUT) couples to the immersion medium, based on an accurate parametric model. We show that the velocity of cMUT membrane can be written as a ...
      Thumbnail

      A novel equivalent circuit model for CMUTs 

      Oğuz, H. Kağan; Olcum, Selim; Senlik, Muhammed N.; Atalar, Abdullah; Köymen, Hayrettin (IEEE, 2009-09)
      A nonlinear equivalent circuit for immersed transmitting capacitive micromachined ultrasonic transducers (CMUTs) is presented. The velocity profile across the CMUT surface maintains the same form over a wide frequency ...
      Thumbnail

      Optimizing CMUT geometry for high power 

      Yamaner F.Y.; Olcum, Selim; Bozkurt, A.; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2010)
      Capacitive micromachined ultrasonic transducers (CMUTs) have demonstratedvarious advantages over piezoelectric transducers. However, current CMUT designsproduce low output pressures with high harmonic distortions. Optimizing ...

      Browse

      All of BUIRCommunities & CollectionsTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartmentsThis CommunityTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartments

      My Account

      LoginRegister

      Discover

      Author
      Atalar, Abdullah (10)
      Köymen, Hayrettin (8)Olcum, Selim (6)Şenlik, Muhammed N. (5)Bozkurt, A. (2)Yamaner F.Y. (2)Bozkurt, A. (1)Ergun, A. S. (1)Olcum, S. (1)Olçum, Selim (1)... View MoreKeywords
      Ultrasonic transducers (10)
      Ultrasonics (10)
      Capacitive micromachined ultrasonic transducer (7)Transducers (5)Capacitive micromachined ultrasonic transducers (3)Radiation impedance (3)Radiation resistance (3)Ultrasonic equipment (3)Ultrasonic measurement (3)Ultrasonic waves (3)... View MoreDate Issued2009 (3)2010 (3)2007 (2)2001 (1)2006 (1)TypeConference Paper (8)Article (2)Has File(s)Yes (10)

      Bilkent University

      If you have trouble accessing this page and need to request an alternate format, contact the site administrator. Phone: (312) 290 1771
      © Bilkent University - Library IT

      Contact Us | Send Feedback | Off-Campus Access | Admin | Privacy