Analytic modeling of loss and cross-coupling in capacitive micromachined ultrasonic transducers
(IEEE, Piscataway, NJ, United States, 1998)
The structural loss mechanism of capacitive micromachined ultrasonic transducer (cMUT) is investigated using finite element analysis and the normal mode theory. A single micromachined transducer membrane on an infinite ...
An equivalent circuit for collapse operation mode of CMUTs
(IEEE, 2010)
Collapse mode of operation of the capacitive mi-cromachined ultrasonic transducers (CMUTs) was shown to be a very effective way for achieving high output pressures. However, no accurate model exists for understanding the ...
Radiation impedance of collapsed capacitive micromachined ultrasonic transducers
(Institute of Electrical and Electronics Engineers, 2012)
The radiation impedance of a capacitive micromachined ultrasonic transducer (CMUT) array is a critical parameter to achieve high performance. In this paper, we present a calculation of the radiation impedance of collapsed, ...
Equivalent circuit-based analysis of CMUT cell dynamics in arrays
(IEEE, 2013)
Capacitive micromachined ultrasonic transducers (CMUTs) are usually composed of large arrays of closely packed cells. In this work, we use an equivalent circuit model to analyze CMUT arrays with multiple cells. We study ...
A novel equivalent circuit model for CMUTs
(IEEE, 2009-09)