• About
  • Policies
  • What is openaccess
  • Library
  • Contact
Advanced search
      Search 
      •   BUIR Home
      • Scholarly Publications
      • Search
      •   BUIR Home
      • Scholarly Publications
      • Search
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Search

      Show Advanced FiltersHide Advanced Filters

      Filters

      Use filters to refine the search results.

      Now showing items 1-9 of 9

      • Sort Options:
      • Relevance
      • Title Asc
      • Title Desc
      • Issue Date Asc
      • Issue Date Desc
      • Results Per Page:
      • 5
      • 10
      • 20
      • 40
      • 60
      • 80
      • 100
      Thumbnail

      An improved lumped element nonlinear circuit model for a circular CMUT cell 

      Köymen, Hayrettin; Atalar, Abdullah; Aydogdu, E.; Kocabas, C.; Oguz, H. K.; Olcum, S.; Ozgurluk, A.; Unlugedik, A. (IEEE, 2012)
      This paper describes a correction and an extension in the previously published large signal equivalent circuit model for a circular capacitive micromachined ultrasonic transducer (CMUT) cell. The force model is rederived ...
      Thumbnail

      Bilateral CMUT cells and arrays: equivalent circuits, diffraction constants, and substrate impedance 

      Köymen, Hayrettin; Atalar, Abdullah; Taşdelen, A. S. (Institute of Electrical and Electronics Engineers Inc., 2017)
      We introduce the large-signal and small-signal equivalent circuit models for a capacitive micromachined ultrasonic transducer (CMUT) cell, which has radiating plates on both sides. We present the diffraction coefficient ...
      Thumbnail

      An equivalent circuit model for transmitting capacitive micromachined ultrasonic transducers in collapse mode 

      Olcum, S.; Yamaner, F. Y.; Bozkurt, A.; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2011)
      The collapse mode of operation of capacitive micromachined ultrasonic transducers (CMUTs) was shown to be a very effective way to achieve high output pressures. However, no accurate analytical or equivalent circuit model ...
      Thumbnail

      An equivalent circuit for collapse operation mode of CMUTs 

      Olcum, Selim; Yamaner F.Y.; Bozkurt, A.; Köymen, Hayrettin; Atalar, Abdullah (IEEE, 2010)
      Collapse mode of operation of the capacitive mi-cromachined ultrasonic transducers (CMUTs) was shown to be a very effective way for achieving high output pressures. However, no accurate model exists for understanding the ...
      Thumbnail

      A novel equivalent circuit model for CMUTs 

      Oğuz, H. Kağan; Olcum, Selim; Senlik, Muhammed N.; Atalar, Abdullah; Köymen, Hayrettin (IEEE, 2009-09)
      A nonlinear equivalent circuit for immersed transmitting capacitive micromachined ultrasonic transducers (CMUTs) is presented. The velocity profile across the CMUT surface maintains the same form over a wide frequency ...
      Thumbnail

      Designing circular CMUT cells using CMUT biasing chart 

      Köymen, Hayrettin; Atalar, Abdullah; Oğuz, H. Kağan (IEEE, 2012-10)
      A very accurate equivalent circuit model for circular CMUT cell is recently proposed. As a consequence of this model, the operating characteristics of the cell is derived and presented as a biasing chart for CMUTs. We ...
      Thumbnail

      Calculation of transformer ratio in mason's equivalent circuit for cMUTs 

      Ölçüm, Selim; Atalar, Abdullah; Köymen, Hayrettin; Şenlik, Muhammed Niyazi (IEEE, 2006)
      We present a new method to calculate the transformer ratio of a cMUT in Mason's Equivalent circuit model. The effect of the spring softening capacitance is also included in the analysis. We use the existing turns ratio ...
      Thumbnail

      Equivalent circuit-based analysis of CMUT cell dynamics in arrays 

      Oğuz, H. K.; Atalar, Abdullah; Köymen, Hayrettin (IEEE, 2013)
      Capacitive micromachined ultrasonic transducers (CMUTs) are usually composed of large arrays of closely packed cells. In this work, we use an equivalent circuit model to analyze CMUT arrays with multiple cells. We study ...
      Thumbnail

      Parametric nonlinear lumped element model for circular CMUTs in collapsed mode 

      Aydoǧdu, E.; Ozgurluk, A.; Atalar, Abdullah; Köymen, Hayrettin (2014)
      We present a parametric equivalent circuit model for a circular CMUT in collapsed mode. First, we calculate the collapsed membrane deflection, utilizing the exact electrical force distribution in the analytical formulation ...

      Browse

      All of BUIRCommunities & CollectionsTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartmentsThis CommunityTitlesAuthorsAdvisorsBy Issue DateKeywordsTypeDepartments

      My Account

      Login

      Discover

      Author
      Atalar, Abdullah (9)
      Köymen, Hayrettin (9)Bozkurt, A. (2)Olcum, S. (2)Olcum, Selim (2)Ozgurluk, A. (2)Oğuz, H. Kağan (2)Aydogdu, E. (1)Aydoǧdu, E. (1)Kocabas, C. (1)... View MoreKeywords
      Equivalent circuit model (9)
      Capacitive micromachined ultrasonic transducer (4)Ultrasonic transducers (4)Circuit theory (3)Finite element method (3)Cells (2)Circuit models (2)Collapse mode (2)Collapse voltage (2)Collapsible tubes (2)... View MoreDate Issued2010 - 2017 (7)2006 - 2009 (2)Has File(s)Yes (9)

      Bilkent University

      If you have trouble accessing this page and need to request an alternate format, contact the site administrator. Phone: (312) 290 1771
      © Bilkent University - Library IT

      Contact Us | Send Feedback | Off-Campus Access | Admin | Privacy